Before starting the engine,
Before starting the engine, make sure that the power rating of power consumers matches that of the generator. Do
not exceed the nominal power of the generator. Do not connect any devices before you start the engine!
Do not connect any devices before you start the engine!
GETTING STARTED
7
Do not change the controller settings in terms of the amount of
fuel or speed governor (this adjustment was made at the factory).
Otherwise, this may result in changes in the engine operation or
its failure.
IMPORTANT!
In the power supply mode, the generator should operate no longer
than 15 minutes in the range from nominal to maximum power.
ATTENTION – DANGER!
COMMISSIONING
In the first 20 operating hours of the generator, the following requirements should be met:
1. During commissioning, do not connect power consumers, the power of which exceeds 50% of the nominal
(operating) power of the device.
2. After commissioning, be sure to change the oil. It is better to drain oil while the engine is still hot after operation
to ensure quick and complete oil draining.
Before starting to use the generator, connect the ground wire to
the ground terminal.
IMPORTANT!
Useful tip: to ensure long-term operation of the generator engine,
it is important to observe the following tips:
- Before connecting the load, allow the engine to run for 1-2 minutes to warm it up.
- When disconnecting the load after lengthy operation, do not turn off the generator. Allow the
generator to run idle for 1-2 minutes so that it cools down.
IMPORTANT!
Do not connect two or more devices at a time. The start-
up of many devices requires high power. Devices should
be connected one at a time according to their power rat-
ing. Do not connect any power consumers within the first
2 minutes after the generator has been started.
ATTENTION – DANGER!
DISCONNECT ALL DEVICES BEFORE STOPPING THE GENERATOR!
Do not stop the generator if it has any devices connected to it. This may disable the generator or devices connected
to it!
ENGINE START
Do not connect any power consumers to the generator before you start the engine. Turn the ECON switch to the “OFF”
position. Turn the air choke control knob to the “CLOSE” position. Turn the fuel valve handle to the “ON” position
(OPEN). Set the engine switch to “ON”. Pull the manual starter until a slight resistance is felt, then pull it toward you
relatively sharply. Slowly turn the manual starter by hand, do not release it abruptly. When starting the generator,
hold the generator by the carrying handle to prevent the generator from falling. Slowly turn the air choke control knob
to the “OPEN” position and then warm up the engine for 1-2 minutes. If the engine does not start, check the oil level.
Before turning on the connected device, check that the ECON switch is in the “OFF” position.
www.ks-power.de/en
|