Boxi II – Manual
4.2
CAN
5
GND
MASTER
TO RADIO
To Nesis T
o Ne
xt
De
vice
GND
PIT
CH TRIM
ROLL TRIM
12
11
10
6
9
8
7
5
4
3
2
1
Figure 3:
Default connection.
Boxi power supply shall be protected with a fuse of a proper rating. The
recommended current rating of the fuse is 5A.
4.2
CAN
Boxi must be connected to primary CAN bus in order to control any supported
Kanardia
device via Joyu (refer to Figure 3). Use standard RJ45 ethernet cable
to connect it with other
Kanardia
devices.
Two identical CAN ports are present on the Boxi device. If the Boxi is the
first or last device on the bus use termination plug on the remaining port.
4.2.1
BLU
If there are no devices present and you want to configure Boxi and Joyu devices
with BLU (Bluetooth CAN interface) you shall use a special RJ45 power cable
for powering the BLU device. The cable connects to one of Boxi CAN ports
12
©