Aetos Installation Manual
10.3
Connection Details
Figure 48:
Home page of the AT1 device. RS-232 data port 3 was not set yet.
1. Change the
RS-232 data port 3 Output
to FLARM PROTOCOL and
2. change the
RS-232 data port 3 RS-232 Data Rate
to 57600.
3. You can also experiment with
Range
and
Vertical Range
settings, but
default values are OK.
4. Press the
Save
button to activate the changes.
Aetos requires a few seconds to detect new data rate and detect the format.
This procedure is automatic.
Unfortunately, AT1 does not fully implement the Flarm protocol. So Ae-
tos can’t obtain device information. An attempt to access any of the ADS-
B/Flarm options on Aetos will result in
Flarm info is not available
message.
This does not mean that AT1 device is not working properly.
10.3.10
Flarm Eagle
Please read the
Flarm Eagle Manual
before any connection is made to Aetos.
The manual can be obtained from the
web
52
©
Kanardia
2019–2020