TECHNICAL DESCRIPTION
ULTRAFLOW® 54 DN150-300
Kamstrup A/S
·
Technical description
·
5512-876_M1_GB_12.2020
11
Programming options of meter factor and pulse durations
Overview of programming options as to meter factors (CC) and pulse durations
(
E) for separate ULTRAFLOW®
q
p
[m³/h]
[p/l]
[l/p]
CC
[ms] (E=1) [ms] (E=4) [ms] (E=5) [ms] (E=6)
150
1
33
3.9
-
-
-
Default
150
10
34
-
20
-
-
150
25
64
-
20
-
-
150
100
35
-
20
50
100
150
250
65
-
20
50
100
150
1000
36
-
20
50
100
150
2500
66
-
20
50
100
250
0.6
43
3.9
-
-
-
Default
250
10
34
-
20
-
-
250
25
64
-
20
-
-
250
100
35
-
20
50
100
250
250
65
-
20
50
100
250
1000
36
-
20
50
100
250
2500
66
-
20
50
100
400
0.4
63
3.9
-
-
-
Default
400
100
35
-
20
50
-
400
250
65
-
20
50
100
400
1000
36
-
20
50
100
400
2500
66
-
20
50
100
600
0.25
14
3.9
-
-
-
Default
600
100
35
-
20
50
-
600
250
65
-
20
50
-
600
1000
36
-
20
50
100
600
2500
66
-
20
50
100
1000
0.15
24
3.9
-
-
-
Default
1000
(0.25)
4
14
3.9
-
-
-
*)
1000
100
35
-
20
50
-
1000
250
65
-
20
50
-
1000
1000
36
-
20
50
100
1000
2500
66
-
20
50
100
*) Spare part for ULTRAFLOW
®
type 65-S/R/T. Configured 65-5-FGCR. No flow info.
Meter factor
Pulse duration
Table 6. Programming options as to meter factor (CC) and
pulse durations (E) for ULTRAFLOW® 54 DN150-300.
Based on a q
p
value a meter factor in
is chosen. The valid possible pulse durations are listed on the same line as
the chosen meter factor.
Example: For ULTRAFLOW® 54 q
p
400 m
3
/h a meter factor of 100 liter/pulse (CC=35) is required. Based on this meter
factor one of the pulse durations, 20 milliseconds (E4) or 50 milliseconds (E5), is selected.
Default values in
are programming values for ULTRAFLOW® 54 when connected to a Kamstrup MULTICAL®
calculator.