Kampmann PowerKon LT Assembly, Installation And Operating Instructions Download Page 49

PowerKon LT

PowerKon LT

Assembly, installation and operating instructions

49

co

o

lin

g cap

aci

ty

(s

e

n

si

b

le

)

h

lle

ist

u

n

g

(sen

sib

el)

co

o

lin

g cap

aci

ty

(l

at

e

n

t)

h

lle

ist

u

n

g

(lat

en

t)

He

at

in

g cap

aci

ty

W

är

me

le

ist

u

n

g

To

tal

 e

le

ct

ri

c p

o

we

r i

n

p

u

t

Ele

kt

risc

h

Gesamt

le

ist

u

n

gsau

fn

ah

me

So

u

n

d

 p

o

we

r l

e

ve

l

(p

e

r s

p

e

e

d

 s

e

tt

in

g,

 if ap

p

licab

le

)

Sc

h

alll

eist

u

n

gsp

ege

l

(gg

f. j

e G

esc

h

w

in

d

ig

ke

it

s-e

in

st

ell

u

n

g)

1

EC

2

EC

3

EC

Cooling Test

Air 
temperature

Test Kühlbetrieb

Luft-
temperatur

Heating Test

Air 
temperature

Test Heizbetrieb

Luft-
temperatur

Sound power test

Test Schallleistungspegel

At ambient conditions without water flow

Bei Umgebungsbedingungen ohne Wasserdurchsatz

Contact Details

Kampmann GmbH & Co. KG

Kontaktinformationen

Friedrich-Ebert-Straße 128-130, D-49811 Lingen (Ems), Germany

20 °C (dry bulb)

Inlet water 
temperature

45 °C for 2-pipe units
65 °C for 4-pipe units

Water temperature 
decrease

5 °C for 2-pipe units

10 °C for 4-pipe units

20 °C (Trockenkugel)

Wassertemperatur am 
Einlass

45 °C für 2-Rohrsysteme
65 °C für 4-Rohrsysteme

Sinken der 
Wassertemperatur

5 °C für 2-Rohrsysteme

10 °C für 4-Rohrsysteme

Standard rating conditions for fan coil units according to regulation (EU) No 2016/2281

Norm-Prüfbedingungen für Gebläsekonvektoren gemäß Verordnung (EU) Nr. 2016/2281

27 °C (dry bulb)

19 °C (wet bulb)

Inlet water 
temperature

7 °C

Water temperature rise

5 °C

27 °C (Trockenkugel)

19 °C (Feuchtkugel)

Wassertemperatur am 
Einlass

Anstieg der 
Wassertemperatur

1,9

0,6

2,9

0,029

49

1,5

0,5

2,2

0,022

48

0,9

0,2

1,3

0,019

49

Information requirements for fan coils according to regulation (EU) No 2016/2281

Informationsanforderungen für Fan Coils gemäß Verordnung (EU) Nr. 2016/2281

PowerKon LT

heating and cooling

Heizen und Kühlen

2-pipe unit

2-Rohrsystem

Model size

Baugöße

Fan

Ventilator

P

rated,c

P

rated,c

P

rated,h

P

elec

L

WA

kW

kW

kW

kW

dB (A)

Summary of Contents for PowerKon LT

Page 1: ...PowerKon LT Assembly installation and operating instructions Keep these instructions in a safe place for future use Issue07 23EN SAP No 1816160...

Page 2: ......

Page 3: ...ruction and function 13 5 1 Overview 13 5 2 Brief description 13 5 3 Wear parts list 13 6 Installation and wiring 14 6 1 Definition of the connection side 14 6 2 Requirements governing the installatio...

Page 4: ...nance 42 10 1 Securing against reconnection 42 10 2 Maintenance Schedule 42 10 3 Maintenance work 43 10 3 1 Clean the inside of the unit 43 10 3 2 Replacing the filter 43 10 3 3 Cleaning the condensat...

Page 5: ...lations apply as do general safety provisions governing the use of the equipment Illustrations in this guide are intended to provide a basic understanding and may differ from the actual model Ongoing...

Page 6: ...ower net work The operating limits and limits of use described in Chapter 2 2 6 must be observed Intended use of the unit also includes adherence to these instructions Information in accordance with E...

Page 7: ...would refer to VDI 2035 Sheets 1 2 DIN EN 14336 and DIN EN 14868 with regard to the properties of the medium used to protect the equipment The following values provide further guidance The water used...

Page 8: ...as switch cabinets computers or other electrical units or contacts that are not drip proof Never use the unit as a construction site heater Never operate the unit in areas with a high dust content IM...

Page 9: ...gained from specialist professional training Safety and accident prevention regulations Guidelines and recognised technical regulations i e Association of German Electricians VDE regulations DIN and...

Page 10: ...nn website IMPORTANT NOTE 2 people are needed to transport the unit Wear personal protective clothing when transporting the unit Only lift the unit on both sides and not by the pipes valves IMPORTANT...

Page 11: ...l vibrations and shocks IMPORTANT NOTE Under certain circumstances packages can carry storage instructions that exceed the requirements listed here Comply with these instructions accordingly 3 4 Packa...

Page 12: ...t of basic unit kg 17 19 7 21 8 Air volume flow m h 110 246 160 369 189 502 Power consumption W 7 3 19 5 11 0 33 0 13 7 34 8 Water content l 0 8 1 2 1 5 Heat output W 9 784 1429 1171 2215 1450 2850 Co...

Page 13: ...ical junction box 5 2 Brief description PowerKon LT are fan assisted and wall mounted convectors heaters for heating and cooling The units silently air condition rooms and their multiple connection op...

Page 14: ...he installation site Only install and assemble the unit if the following conditions are met Ensure that the unit is securely suspended Ensure that the airflow can circulate freely Provide adequate spa...

Page 15: ...on LT minimum clearances This area needs to be kept as free as possible to ensure that the air can flow freely out of the air outlet grille Window sills should be a minimum of 10 cm from the air outle...

Page 16: ...RTANT NOTE Horizontal installation of units When installing the units ensure that they are completely horizontal to ensure proper operation IMPORTANT NOTE Avoid draughts Consider the occupied zone whe...

Page 17: ...PowerKon LT PowerKon LT Assembly installation and operating instructions 17 6 4 1 Installing the unit...

Page 18: ...PowerKon LT PowerKon LT Assembly installation and operating instructions 18 780 1030 1220 141 618 Fig 4 PowerKon LT dimensions...

Page 19: ...oosen the thermostatic valve and return shut off valve Remove the heater and dismantle the existing fitting from the wall Position the fixing rail for PowerKon LT level and fix in place Prepare the ex...

Page 20: ...erKon LT 6 5 Installation Actuator with First Open function When delivered the actuator is normally open in a de energised state thanks to the First Open function This enables heating mode to run even...

Page 21: ...here is a danger to the user from cold temperatures and a danger to the environment from the use of glycol Put in place appropriate safety measures Remove protective caps from the supply and return Wi...

Page 22: ...nless steel corrugated pipes 1 2 connection on right KVS value 1 7 m h PowerKon LT DN 15 129012200201 Differential pressure inde pendent thermostatic valve 2 pipe includes pre set table valve angled r...

Page 23: ...n nection supplied separately All models connection on left 129013100000 Cooling accessory kit Accessory kit for cooling with condensate for con densate drainage with a natural gradient consisting of...

Page 24: ...contact is triggered to prevent the condensate tray from overflowing Condensate drain Ensure that drainage of condensate from the condensate pump runs along a natural gradient with an adequate cross s...

Page 25: ...separately 1290131100 00 Condensate pump set sup plied separately Condensate pump for cooling below the dew point for the discharge of condensate pro duced 50 60 Hz consisting of valve con densate tr...

Page 26: ...h automatic universal power input detection Output 8 W at maximum operation at 110 V Alarm relay 7 amp contacts with integrated replaceable 6 3 A fuse 5 20 mm Weight 1 000 g 2 2 lb Discharge star pipe...

Page 27: ...de Or LED displays in operation The pump features 3 extra long running cycles and reconfigures the DIP switches for more capacity Red The pump cannot keep up with the water feed To prevent the water f...

Page 28: ...ectrical rating values PowerKon LT 7 2 Electromechanical connection 230 V 00 Circuit description 00 Factory fitted actuators are wired to the terminals The appropriate terminals are available for valv...

Page 29: ...tive type F For the design of the rated residual current the specifications from DIN VDE 0100 Parts 400 and 500 must be observed For the design of the on site mains supply and fuse protection C16A max...

Page 30: ...site Observe the Electrical data table Main supply 230V PowerKon LT Electromechanical Unit no 1 Building Automation BA Valve actuator Open Close Unit 2 Valve actuator Open Close Unit 1 Speed unit No 2...

Page 31: ...ction on site Observe the Electrical data table Main supply 230V 1 2 gn ge gn ge 1 L N PE GND Uc VHi 1 2 3 4 Ri 100 K 4 2 3 3 W1 3 W2 1 2 2 5 4 3 2 1 GND VH Uc 24V DI 4 3 Room thermostat Type 342924 2...

Page 32: ...e g Heat Cool Contact e g window Climate controller Type 30155 optional More information see Instruction Climate controller L N PE GND Uc VHi 1 2 3 4 Ri 100 K N PE L 1 2 gn ge Main supply 230V Fuse pr...

Page 33: ...at Optionally 3 level fan stages can be selected using a rocker switch Fig 8 Control curves IV DIP 1 0 DIP 2 1 max 8 V at stage 3 DIP1 DIP2 Factory setting DIP switch function 0 0 Test mode 1 0 Switch...

Page 34: ...nection cable with a standard European plug 1 Power supply 230 V 2 Condensate pump power supply 230 V 3 Valve drive s 230 V Open Closed 4 Heat pump contact On Off potential free 5 Heat pump contact he...

Page 35: ...ntly on ON 6 Heating fan operation Thermostatic control Permanently on ON 7 Fan switch off delay No delay 3 minutes ON 8 Master slave Master Slave OFF Tab 10 DIP switch Jumper Function Open Closed Sta...

Page 36: ...tive type F For the design of the rated residual current the specifications from DIN VDE 0100 Parts 400 and 500 must be observed For the design of the on site mains supply and fuse protection C16A max...

Page 37: ...2 3 DI2 Heat pumps heating cooling DI3 4 5 RS485 1 RS485 2 1 3 2 1 2 3 Twisted Pair Main supply 230V Fuse protection on site Observe the Electrical data table HP On OFF HP H C 1 2 3 4 5 5 W1 DI1 HP O...

Page 38: ...et in accordance with the wiring diagram Water side checks Check whether all supply and drainage lines have been properly connected Fill pipes and unit with water and bleed Check whether all bleed scr...

Page 39: ...n Automatic fan 3 stage switch for pre selecting the fan speed when the operating mode selector switch is in the Manual fan position option for external room sensor connection control input for heatin...

Page 40: ...low temperature T2 is not reached Lit red Heating mode Lit blue Cooling mode The following messages appear on the display in the event of an alarm Message Flash code Meaning Unit status AL1 1x flashin...

Page 41: ...999 2 0 1 Off display is automatically switched off 30 seconds after the last operation 2 Password 022 Extended parameters Parameter Description Setting Standard F rt Filter run time RO F rS Filter re...

Page 42: ...nd teat Contact the manufacturer with any questions about maintenance work and intervals Interval Maintenance task Personnel As required Regular visual checks and acoustic checks for damage dirt and f...

Page 43: ...rt or deposits dur ing maintenance and use a commercially available product to remove Remove the casing upwards When refitting make sure that the side recesses are sitting correctly on the wall bracke...

Page 44: ...n LT PowerKon LT Assembly installation and operating instructions 44 10 3 3 Cleaning the condensate tray Clean the condensate tray 10 3 4 Cleaning the valve condensation tray Clean the valve condensat...

Page 45: ...ormation Behaviour in the event of faults The following applies 1 Immediately switch off the unit with faults that pose an immediate danger to persons or property 2 Determine the cause of the fault 3...

Page 46: ...nit system Valves not operating Replace faulty valves Water volume too low Check pump output check hydraulics Setpoint temperature on the controller set too low high Adjust temperature setting on the...

Page 47: ...article Typ Model Nr artyku u Typ Model slo v robku auf das sich diese Erkl rung bezieht mit der den folgenden Norm en oder normativen Dokumenten bereinstimmt to which this declaration relates is in c...

Page 48: ...2009 125 EG ErP Richtlinie 2016 2281 EU Durchf hrungsverordnung f r Luftheizungsprodukte K hlungsprodukte Prozessk hler mit hoher Betriebstemperatur und Gebl sekonvektoren Frank Bolkenius Lingen Ems...

Page 49: ...45 C for 2 pipe units 65 C for 4 pipe units Water temperature decrease 5 C for 2 pipe units 10 C for 4 pipe units 20 C Trockenkugel Wassertemperatur am Einlass 45 C f r 2 Rohrsysteme 65 C f r 4 Rohrs...

Page 50: ...Tab 2 Operating voltage 7 Tab 3 Water quality 7 Tab 4 Technical data 12 Tab 5 Condensate accessories 25 Tab 6 Technical data for condensate pump 26 Tab 7 Maximum electrical rating values 28 Tab 8 DIP...

Page 51: ......

Page 52: ...ac products fan coils powerkon lt Country Contact Great Britain Kampmann UK Ltd Dial House Govett Avenue Shepperton Middlesex TW17 8AG T 44 1932 228592 F 44 1932 228949 E info kampmann co uk W Kampman...

Reviews: