Kamoer fluid tech(Shanghai)Co., Ltd.                                                          UIP WIFI User Manual 

 

 

8   

this function to copy a volume first; 

h, working volume:

 display the working volume, when the ration mode starts working, the value 

decreases with the work of the pump, indicating the working process; 

i. Pause time:

 the interval between each filling in the automatic mode of the ration mode; 

j.  Cycle  mode  and  progress  display:

  The  ration  mode  has  two  modes:  full-automatic  and 

semi-automatic.  When  working  in  semi-automatic  mode,  the  number  represents  the  number  of 

times of work. When working  in the fully  automatic  mode, the number format is the number  of 

times of work. / target work times; 

k.  Settings:

  Click  to  enter  the  ration  mode  setting  interface.  For  details,  see  2.2.1  Ration  Mode 

Settings. 

l, Direction button:

 click to switch the direction of rotation of the pump, set when the pump stops 

running, can not operate when the pump is running; 

m, Pause time:

 Click to set the allocation mode pause time, the unit is second; 

n,  The  number  of  cycles:

  click  the  number  of  cycles  to  set  the  automatic  mode  of  the  ration 

mode; 

o,  Start/Stop  button:

  assign  mode  start  stop  button;  in  semi-automatic  mode,  when  the  set 

working  volume  finishes  running,  the  ration  mode  stops  automatically.  In  the  fully  automatic 

mode, when the cycle number runs out, the ration mode stops automatically; 

p,  Wi-Fi  status  display:

  Here  shows  the  status  of  Wi-Fi,  the  specific  Wi-Fi  status  refers  to  3.2 

ration network chapter; 

 

2.2.1 Ration mode setting 

In  the  ration  mode,  click  the  "Settings"  button  in  the  lower  left  corner  to  enter  the  ration 

mode setting interface: 

 

Figure 2-2-1-1 Assignment Mode Settings 

a. Tube type setting:

 Click to enter the tube type selection interface and select the corresponding 

Summary of Contents for UIP CK15

Page 1: ...UIP WIFI smart peristaltic pump User Manual Version A 0 Kamoer fluid tech Shanghai Co Ltd www kamoer com www ecounit kz...

Page 2: ...ON 12 2 5 WI FI REMOTE CONTROL 14 2 6 485 REMOTE CONTROL 14 2 7 CAN REMOTE CONTROL 14 3 APP RUNNING OPERATION 14 3 1 DOWNLOAD KAMOER PUMPS APP 14 3 2 RATION NETWORK 15 3 3 APP MODULE INTRODUCTION 21 3...

Page 3: ...ntinued the model is similar The free service does not include shipping costs for the product due to repairs 3 Non warranty coverage The following factors is not within the scope of free warranty cust...

Page 4: ...les to avoid danger If you find any visible damage please do not switch on Be sure not to use in humid environment avoid damage by short circuit Temperature changes or mechanical wear may cause the in...

Page 5: ...nformation 1 1 About UIP series peristaltic pump is using stepping motor control commonly used in low traffic and high precision setting configure the touch screen 480 x 272 powerful easy to operate P...

Page 6: ...cation interface connect RJ45 connector CAN communication line can remotely control the machine through CAN 5 RS485 communication interface connect RJ45 connector RS485 communication line remotely con...

Page 7: ...ontinuous mode applied to the scene where the pump continues to run for a long time After the start the pump will run all the time click the pump again to stop the operation the flow rate can be adjus...

Page 8: ...ding to the current flow rate setting d Temperature display the temperature of the external temperature sensor when the external sensor is not connected it is displayed here e Flow rate display displa...

Page 9: ...e a Tube type setting Click to enter the tube type selection interface and select the corresponding tube type Each tube type has a corresponding relationship between the speed and the flow rate If not...

Page 10: ...king and an alarm prompt is given in continuous mode click Set Level Detection to enter the continuous mode level detection setting interface Figure 2 2 2 1 Continuous mode liquid level detection sett...

Page 11: ...quantitative are equal the pump stops running and the middle of the screen begins to The pause time countdown when the countdown is 0 the pump automatically restarts the work the pump runs once and re...

Page 12: ...utton click to switch the direction of rotation of the pump set when the pump stops running can not operate when the pump is running m Pause time Click to set the allocation mode pause time the unit i...

Page 13: ...is detected the pump stops working and an alarm is given d Foot switch Click to switch the opening and closing of the foot switch control If the foot switch is turned on the continuous mode can be co...

Page 14: ...tate of floating and sinking of different liquid level floats is different Here choose which state the float is used as an alarm 2 2 3 Ration mode copy volume The copy volume is used when the working...

Page 15: ...on mode c Speed ration mode speed according to the ration mode flow rate setting conversion d Run volume the real time volume after the start of replication e Prime Before starting to copy you need to...

Page 16: ...e real time clock of the machine e System information click to enter the display system information including firmware version model number serial number f System self test check whether the functions...

Page 17: ...mp starts running the calibration progress will show the progress When the calibration time countdown is completed the pump stops running the interface will pop up the input box and the volume obtaine...

Page 18: ...r in the winch and click OK to complete the calibration 2 5 Wi Fi remote control Refer to the third chapter APP operation 2 6 485 remote control UIP includes 485 remote control function For details pl...

Page 19: ...sing pump Wi Fi in the Wi Fi list of the mobile phone the name starts with KAMOER followed by the 5 digit serial number the connection password is a12345678 and the user directly connects to the Wi Fi...

Page 20: ...1 Power on and click on the title bar to enter the system settings interface Step 2 Click Wi Fi Settings to enter the connection mode selection interface Step 3 Select Wi Fi reset in the pop up conne...

Page 21: ...election interface Step 3 Select a one click connection in the pop up connection mode dialog box to enter a one click connection waiting interface Step 4 Open the Kamoer Pumps App and follow the promp...

Page 22: ...Kamoer fluid tech Shanghai Co Ltd UIP WIFI User Manual 18...

Page 23: ...Kamoer fluid tech Shanghai Co Ltd UIP WIFI User Manual 19...

Page 24: ...Kamoer fluid tech Shanghai Co Ltd UIP WIFI User Manual 20...

Page 25: ...es as follows 1 Continuous mode continuous mode title where you can switch the allocation mode 2 Assignment mode Assign the mode title where you can switch to continuous mode 3 Settings system setting...

Page 26: ...celeration button deceleration button is clicked 3 Flow rate Click the pop up keyboard to set the flow rate directly 4 Acceleration deceleration button Click the button to accelerate or decelerate Whe...

Page 27: ...and stops the motor 3 5 Ration mode In the ration mode there are two working modes namely a fully automatic working mode and a semi automatic working mode 1 Semi automatic working mode the user sets...

Page 28: ...unning and the trigger starts again and then runs again 3 Edit Click to enter the ration mode parameter setting interface 4 Working volume the volume of the single mode of the ration mode set in the e...

Page 29: ...ode working volume does not know how much input use the copy function to get the required volume For details refer to the copy function introduction 5 Flow rate set the ration mode flow rate 6 Pause d...

Page 30: ...he ration mode copy function interface 2 Copy volume When the copy function is running the volume increases cumulatively 3 Priming Before starting to copy you need to empty the air in the pump tube Cl...

Page 31: ...ntinuous mode or ration mode to enter the system setting interface 2 Tube type setting Click the tube type to enter the tube type calibration interface 3 Restore factory settings Click to restore fact...

Page 32: ...ion will be more accurate if the calibration container allows it 5 Start dosing Click to start dosing the pump starts running when the calibration time countdown is completed the pump stops running in...

Page 33: ...you encounter any problems after use please contact the manufacturer In order to expedite the service please inform your instrument model or serial number Please specify if there is any special appli...

Page 34: ...on Quantit y 1 UIP peristaltic Machine pump 1 2 Power wire 10A AC250V 1 3 User manual English 1 Kamoer Kamoer text and icons are registered trademarks of Kamoer Fluid Technology Shanghai Co Ltd The co...