Kamoer Fluid Tech(Shanghai) Co.,Ltd Reef Master CMK User Manual
31
h.
Range ; For safety reasons, automatic adjustment parameters will take effect within this
parameter range. Once the Reef Master detects a parameter that exceeds this range, automatic
adjustment will not take effect
i.
Adjustment method; There are two adjustment methods, one is proportional adjustment, and
the other is quantitative adjustment. Proportional adjustment is based on the detected water
quality parameters, adjusting a proportion of the titration plan to complete the adjustment.
Quantitative adjustment is based on the detected water quality parameters, adjusting a fixed
amount for adjustment
j.
Adjust Times, which represents the number of titrations required to complete this adjustment
k.
Stop Adjusting; When you want to stop the adjustment of the titration pump, you can click to
stop this adjustment
l.
Examples of adjusting according to proportion and quantity. For those who are unclear
about the adjustment method, please refer to the examples for understanding
Use of Calcium Reactor Equipment
There are two ways to connect and control the calcium reactor. One is to connect the Reef Master
and FX-STP calcium reactor pump through KH Carer E1, and adjust the water quality parameters by
controlling the start and stop of the calcium reactor pump based on the detected value; One
method is to adjust water quality parameters by linking cloud servers and adjusting the speed of
the calcium reactor pump through detection values.
The reference for controlling the calcium reactor is the detection parameters of KH, and the start
and stop of the calcium reactor pump are controlled based on the value of KH