On the status homepage, click “Keep Value Balance” to enable the function, and then enter
the linkage parameter setting interface;
b.
Maintain a stable value switch. When this switch is turned on, the linkage control function
takes effect. When this switch is turned off, the linkage function does not work
c.
Parameter retention value setting; For example, setting a calcium retention value of 450ppm.
When the detected calcium value is below 450ppm, the titration will adjust the amount of
calcium reagent added to bring the detection value back to 450ppm
d.
Add elements; Set Reef Master binding devices and their parameters here, such as titration
pumps and calcium reflux pumps
e.
Tank Volume, which refers to the volume of water in the cylinder. The equipment will calculate
the amount that needs to be adjusted based on the volume of water in the cylinder and the
current concentration of elements. Therefore, this volume should be filled in carefully and
default parameters should not be used
f.
The amount of seawater used; The amount of seawater used by the equipment statistics
Device Binding
The adjustment of elements can be achieved through titration pumps and calcium reactor pumps.
The titration pump is relatively flexible and can be selected for titration adjustment based on
various element parameters. The calcium reactor pump is only adjusted through KH; The titration
pump needs to have a wired communication interface, such as F4 PRO, DDP4, DDP4 PRO, etc.
The titration pump and the calcium reactor pump can simultaneously participate in regulating
water quality parameters.