Important Safeguards For All  

Electrical Appliances

•   Carefully read all instructions before operating 

the appliance and save for future reference.

•   Remove and safely discard all packaging 

material and promotional labels before using 

the appliance for the first time.

•   Fully unwind the power cord before use.
•   Do not let the power cord hang over the edge 

of a bench or table, touch hot surfaces or 

become knotted.

•   To protect against electric shock, do not 

immerse the power cord, power plug or 

appliance in water or any other liquid, unless it 

is recommended in the cleaning instructions.

•   The appliance is not intended for use by 

persons (including children) with reduced 

physical, sensory or mental capabilities, or lack 

of experience and knowledge, unless they 

have been given supervision or instruction 

concerning use of the appliance, by a person 

responsible for their safety.

•   Children should be supervised to ensure that 

they do not play with the appliance.

•   It is recommended to inspect the appliance 

regularly. Do not use the appliance if the 

power supply cord, plug, connector or 

appliance becomes damaged in anyway.  

Return the entire appliance to the nearest 

authorised Kambrook Service Centre for 

examination and/or repair.

•   Any maintenance other than cleaning should 

be performed at an authorised Kambrook 

Service Centre.

•   This appliance is for household use only. 

Do not use this appliance for other than its 

intended use. Do not use in moving vehicles or 

boats.  

Do not use outdoors. 

Misuse may cause injury.

•   The installation of a residual current device 

(safety switch) is recommended to provide 

additional safety protection when using 

electrical appliances. It is advisable that a 

safety switch with a rated residual operating 

current not exceeding 30mA be installed in 

the electrical circuit supplying the appliance.  

See your electrician for professional advice

•   Always turn the appliance to the OFF 

position, switch off at the power outlet 

and unplug at the power outlet when the 

appliance is not in use.

•   Before cleaning, always turn the appliance 

to the OFF position, switch off at the power 

outlet, unplug at the power outlet and remove 

the power cord, if detachable, from the 

appliance and allow all parts to cool.

•   Do not place this appliance on or near a heat 

source, such as hot plate, oven or heaters. 

•   Position the appliance at a minimum 

distance of 20cm away from walls, curtains 

and other heat or steam sensitive materials 

and provide adequate space above and on 
all sides for air circulation. 

•  To avoid an electrical overload, it is 

recommended that no other appliances are 

plugged into the same circuit as your vacuum 

cleaner when it is in use.

•  Dirty and clogged filters may result in reduced 

suction performance. It is recommended 

that filters are cleaned after every use and 

replaced regularly to ensure maximum 

efficiency from your vacuum cleaner. If filters 

are left unclean it may results in reduction of 

suction power.

•  Clean the floor tools regularly. Remove hair, 

cotton and the likes from the turbo brush 

head (for models KBV450 and KBV480 only) 

by cutting across the hair, cotton and the likes 

and by gently pulling it free.

•  Keep the vacuum cleaner clean. Follow the 

cleaning instructions provided in this book..

Summary of Contents for CaptivG3 Cyclonic

Page 1: ...stralia Building 2 Port Air Industrial Estate 1A Hale Street Botany NSW 2019 Australia Customer Service Line 1300 139 798 Customer Service Fax 1800 621 337 www kambrook com au Kambrook New Zealand Private Bag 94411 Botany Manukau Auckland 2163 New Zealand Customer Service Line Spare Parts 0800 273 845 Customer Service Fax 0800 288 513 www kambrook co nz ...

Page 2: ...CaptivG3 Cyclonic Bagless Vacuum ALL MODELS KBV420 450 480 Instruction Booklet ...

Page 3: ...use In the event that you need some assistance with your Kambrook appliance please contact our Customer Service Department on 1300 139 798 Australia or 0800 273 845 New Zealand Alternatively visit us on our website at www kambrook com au or www kambrook co nz ...

Page 4: ...Contents Kambrook Recommends p4 Safety First Your CaptivG3 Cyclonic p6 Bagless Vacuum Operating Instructions p7 Care and Maintenance p10 Troubleshooting p15 ...

Page 5: ... vacuum cleaner without a dust container and motor protection filter in place Never pick up anything that is burning or smoking such as cigarettes matches or hot ashes Avoid picking up hard sharp objects with the vacuum as they may damage the canister filter or motor Do not use the vacuum to pick up flammable or poisonous liquids such as petrol copier toner or other volatile substances Do not use ...

Page 6: ... installation of a residual current device safety switch is recommended to provide additional safety protection when using electrical appliances It is advisable that a safety switch with a rated residual operating current not exceeding 30mA be installed in the electrical circuit supplying the appliance See your electrician for professional advice Always turn the appliance to the OFF position switc...

Page 7: ...sh picks up pet hair from carpet making it ideal for homes with pets KBV450 and KBV480 models only 7 Hard floor tool for improved pick up on hard floors KBV480 only 8 Telescopic chrome steel wand is easily extendable or retractable for varying height requirements 9 Cyclonic cone helps separate particles from the air before filtering begins 10 Two washable HEPA filters included 11 Auto cord rewind ...

Page 8: ...sure that you do not over extend the power cord do not extend past the red warning tape on the cord Plug into a 230V or 240V power point and switch the power on at the power point To commence vacuuming push down on the on off button on off cord press lift up down on the top of the vacuum cleaner When vacuuming is complete push down on the on off button to switch off Turn the power off at the outle...

Page 9: ... MAX marking for vacuuming hard floor and carpet surfaces Slide the lever toward the MIN marking when using the crevice upholstery and brush tools Fig 3 Operating Instructions continued Crevice and Brush Tool Accessories Fig 4 The crevice tool is ideal for vacuuming hard to reach places such as the edges along skirting boards The brush and upholstery tools can be used to vacuum delicate surfaces a...

Page 10: ...king up dirt and hair brushing them back into the nozzle It is great for cleaning carpets and homes with pets Hard Floor Tool KBV480 Only Fig 7 The hard floor tool is ideal for vacuuming hard floors with improved pick up Simply fit the hard floor tool to the narrow end of the wand and push together firmly ...

Page 11: ...ry use When the dust container reaches the capacity mark MAX it is essential to thoroughly clean both the dust container and filters To remove the dust container ensure the vacuum is down on its wheels remove the dust container by pressing down on the button on top of the dust container Once released carefully lift the container upwards Fig 8 Care and Maintenance Fig 9 To empty the dust container ...

Page 12: ...ower outlet and unplug prior to cleaning or replacing the filters Before replacing the filters ensure all dirt and dust is first emptied from the dust container Refer to the EMPTYING THE DUST CONTAINER section 1 Remove the dust container from the vacuum by pressing down on the button on top of the dust container Once released carefully lift the container upwards Your new vacuum cleaner includes a ...

Page 13: ... the vacuum Failure to allow the filter to completely dry may result in damage to the vacuum motor Care and Maintenance continued NOTE A second HEPA filter is supplied for convenience ideal for when a used filter is being cleaned Fig 14 NOTE When replacing the dust container HEPA filter all three components HEPA filter foam filter and plastic casing need to be replaced 4 To place the filter back i...

Page 14: ...tainer has been emptied Follow the EMPTYING THE DUST CONTAINER instructions Press the PUSH button located beneath the hose inlet connection on the front of the dust container The bottom of the container will release Grip the two pockets at the base of the cone with two fingers twist clockwise to OPEN and pull to remove the cone Fig 15 Fig 16 Shake and tap the cone until all the fine dust particles...

Page 15: ... The exhaust filter should be cleaned after every use for maximum vacuuming performance To clean simply unclip the grill at the back of the vacuum cleaner and shake and tap the filter to remove any dust accumulated Then relocate the filter and reattach the grill Care and Maintenance continued ...

Page 16: ...tly Hose is not fitted correctly Dust container is full Ensure the power plug is securely plugged Empty and clean the dust container Refer to Cleaning and Replacing Filters page 11 Check dust container replacement Check dust container installation Check hose installation Empty and clean the dust container Spare Parts To order spare parts for your Kambrook CaptivG3 Cyclonic Bagless Vacuum please co...