For your safety, the frequency
of cleaning the smoke discharge
system must be determined on
the basis of how the Hydro Insert is used.
Exchanger cleaning
Remove the combustion chamber plate to remove it,
push the plate upwards and then rotate it towards the
front.
On the front there are two inspection plates, remove
them and clean the compartment with an ash-cleaner.
Clean fl ue
Clean the fl ue system especially near the fi ttings to “T”,
curves and any horizontal sections. Is necessary to check
and remove any deposit of ash and soot before the same
clogging the passage of smoke.
CLEANING BY THE TECHNICAL
Check every year
Compartment ventilation fl ue gas cleaning
Remove the fi xing screws and remove the smoke fan for
cleaning of the same. Perform the task with the greatest
care not to bend the fan blades.
1
3
Extract the chimney insert using the appropriate
handles and remove the protective casing.
2
2a
2c
2b
1a
1c
1b
In case of failure or inadequate cleaning of the heater may
have function problems such as:
• poor combustion
• blackening of the glass
• clogging of grate with accumulation of ash and pellets
• ash deposit and excessive deposits on the heat
exchanger resulting in poor performance.
The check of electromechanical components must be
performed only by qualifi ed personnel with technical
knowledge of electricity and combustion. Once the
cleaning operations have been completed, reassemble
and fi x the parts.
Remove the insulation,
clean the exchanger and
scrape the pipes where the
fumes pass.