background image

INSTALLATION INSTRUCTIONS

   Pressure  Balance  Trim  

1491056-2-

A

2 of 14

Questions? Problems? For additional assistance, please contact KALLISTA’s Customer

Service Department at 1-888-4-KALLISTA (1-888-452-5547) or kallista.com.

IMPORTANT INSTRUCTIONS

READ AND SAVE FOR THE CONSUMER

WARNING: Risk of scalding or other severe injury.

 

Before completing installation, the installer must set the maximum water temperature setting of this valve to 

minimize the risks associated with scalding hazards according to ASTM F 444.

 

Do not install a shut-off device on either outlet of this valve. The installation of any such device may create 

a cross-flow condition at the valve and affect the water temperature.

 

Factors that change the temperature of the water supplied to the valve, such as seasonal water 

temperature changes, and water heater replacement or servicing, will change the maximum water 

temperature supplied by the valve and may create a scalding hazard. The pressure-balanced valve will not 

compensate for changes in the water supply temperature; adjust the maximum water temperature setting of 

this pressure-balanced valve when such changes occur.

 

Pressure-balanced valves may not provide protection against scalding if there is a failure of other 

temperature-limiting devices elsewhere in the plumbing system.

NOTICE:

 Only apply silicone based lubricants to these valves. Do not use petroleum based lubricants. 

Petroleum based lubricants will harm the O-rings, seals, and plastic components.

The installer is responsible for installing the valve and adjusting the maximum water temperature of 

this pressure-balanced valve according to instructions.
This valve meets or exceeds ANSI A112.18.1 and ASSE 1016.

If you do not understand any of the installation or temperature adjustment instructions in this document, in the 

United States please contact 1-888-4KALLISTA. Outside the U.S., please contact your distributor.

IMPORTANT NOTICE TO INSTALLERS! 

Please fill in the blanks in the adjacent box and on the valve label. 

Then insert these instructions into the plastic bag included with the valve package, and attach the plastic bag 

to the valve handle for the homeowner’s reference.

NOTICE TO HOMEOWNERS!  This device has been preset by _______________________ of 

_______________________________ to ensure a safe maximum temperature.
Any change in the setting may raise the discharge temperature above the limit considered safe, and 

lead to scalds. 
Date: ______________

Summary of Contents for ONE P24415-CR-CP

Page 1: ...rim 1491056 2 A 1 of 14 Questions Problems For additional assistance please contact KALLISTA s Customer Service Department at 1 888 4 KALLISTA 1 888 452 5547 or kallista com P24015 P24016 P24115 P2411...

Page 2: ...ch changes occur Pressure balanced valves may not provide protection against scalding if there is a failure of other temperature limiting devices elsewhere in the plumbing system NOTICE Only apply sil...

Page 3: ...us at the phone number listed at the bottom of the page BEFORE YOU BEGIN Observe all local plumbing and building codes Shut off the main water supply The finished wall or bath shower unit must be ins...

Page 4: ...ve clockwise to the full open position After several minutes check the temperature For minor temperature changes adjust the setscrew and recheck the temperature For major temperature changes remove th...

Page 5: ...nt Fit diverter seal over diverter actuator if applicable and valve seal over valve stem as shown Align the notches in the valve seal with the threaded holes in the valve Install the faceplate onto th...

Page 6: ...ent ne pas assurer une protection contre les br lures en cas de d faillance d autres dispositifs de limitation de temp rature install s ailleurs sur le r seau de plomberie AVIS Seuls des lubrifiants b...

Page 7: ...iqu en bas de page AVANT DE COMMENCER Respecter tous les codes de plomberie et du b timent locaux Couper l alimentation en eau principale Le mur fini ou la baignoire douche doivent tre install s avant...

Page 8: ...temp rature Pour des changements de temp rature importants retirer le joint torique et le collier Tourner lentement la tige de la vanne pour r gler la temp rature maximum de l eau R installer le colli...

Page 9: ...oint d tanch it de la vanne avec les trous filet s dans la vanne Installer la face avant sur la vanne S curiser avec deux vis Ne pas trop serrer Tourner la tige de la vanne compl tement dans le sens a...

Page 10: ...s de presi n no protejan contra quemaduras si otros aparatos de limitaci n de temperatura en el sistema de plomer a no funcionan correctamente AVISO Solo aplique lubricantes derivados de silicona a es...

Page 11: ...fono que se encuentra en la parte inferior de la p gina ANTES DE COMENZAR Cumpla todos los c digos locales de plomer a y de construcci n Cierre el suministro principal de agua Antes de instalar esta...

Page 12: ...inutos revise la temperatura En cambios menores de temperatura del agua ajuste el tornillo de fijaci n y vuelva a verificar la temperatura En cambios mayores de temperatura del agua retire el arosello...

Page 13: ...bre el accionador del desviador si corresponde y un sello de la v lvula sobre el v stago de la v lvula como se indica Alinee las muescas en el sello de la v lvula con los orificios roscados en la v lv...

Page 14: ...produit sur le site kallista com Entretien et le nettoyage kallista com resources product care Brevets kohlercompany com patents Garantie Ce produit est couvert sous la garantie limit e de cinq ans d...

Reviews: