Installation  

To successfully install the Captis device you must perform the following steps: 

1.  Mount the device  
2.  Terminate the sensor  
3.  Test the sensor  
4.  Test connectivity 

1.1 

Mount the Device  

 

The Captis device may be mounted in a range of positions using either:  

 

Screw mounting via the top and bottom tabs to a flat surface; or,  

 

Fasting to a pole/post with a hose clamp (<15mm thick) or cable ties 

 

Upon successfully mounting the device, care must be taken to ensure that there is no undue stress on 
the cable between the sensor and the device. If the sensor cable does become strained in the final 
location, please remove the device, and relocate closer to the sensor.  

1.2 

Terminate the Sensor  

Your Captis Pulse Lite is provided with a four-pin Amphenol plug that can be connected to one or two 
sensors and/or measurement devices. For additional information, refer to the Captis Termination 
guide. 

Use a crimping tool (not included) to ensure that the pins are securely fastened to the end of the 
sensor cable and insert into the appropriate receptacles of the Amphenol plug. 

A light tug on the cables will ensure that the pins are inserted and crimped correctly. 

Use the table below to identify the connections between the Captis Pulse Lite and the sensor via the 
provided Amphenol plug. 

 

 

Note: If the Captis Pulse Lite is to be installed underground or inside a metal cabinet, an 

external LTE antenna must be used. Ensure that your Captis device supports external 

antenna connection. The antenna lead must be routed to an open area where cell signal is 

less obstructed. 