4) Return to Factory Menu, check the Product model.
5) Choose Factory Menu->NVM RESET and press the right button of
the remote and wait until prompt OK appears.
6) Restart the set
7) According to the requirement of the order, Set the items of
SHOP INIT and Hotel Menu etc.
8) After aging under normal temperature, calibrate ADC and adjust
white balance.
9) Choose Factory Menu ->SHOP and press the button of remote to
initialize the set.
Note: After step 9, Hotel Menu will be disabled by default. Therefore,
if the order requires hotel function, it is necessary to enable hotel
function by set Design MENU->Service Menu->HOTEL ENABLE to ON.
5.2. Equipments
·Color Analyzer CA-210.
·Video Pattern Generator Chroma2329.
·Color TV Pattern Generator PM5418/Fluke5418.
·VGA cable , AV(RCA) cable ,YPBPB (RCA) cable, HDMI cable etc.
5.3. ADC Calibration
5.3.1. Signal and generator
PC: Chroma2329 Pattern 42,Timing 14(1024X768@60Hz 5 MOSAIC)
YPBPR: Chroma2329 pattern 103, Timing 79(100% Color Bar,720p)
5.3.2. Steps of Calibration:
1). Access to the Factory menu->ADC