Kalfire W66/48S, W53/50R and W80/52T
•
2 aluminium hoses Ø150 mm 1.25 m: two 2.5-m hoses to be
divided into 4 hoses.
•
8 clamping strips.
•
4 grills: outer dimensions 20 cm × 20 cm, reserve
dimensions 16.5 cm × 16.5 cm, with connecting
collar Ø150 mm.
The mantle iron (including accessories) for the Kalfire w66/48s
and w90/47C models must be ordered separately.
Kalfire W90/47S
•
2 aluminium hoses Ø150 mm 1.25 m: one 2.5-m hose to be
divided into 2 hoses.
•
4 clamping strips.
•
2 grills: outer dimensions 20 cm × 20 cm, reserve
dimensions 16.5 cm × 16.5 cm, with connecting
collar Ø150 mm.
•
2 grills: outer dimensions 35 cm × 20 cm, reserve
dimensions 33 cm × 16.5 cm, with connecting collar Ø150
mm.
The mantle iron (including accessories) for the Kalfire w90/47s
model must be ordered separately.
Kalfire W105/47T
•
8 aluminium hoses Ø150 mm 4× 1.25-m long and 4 × 0.62 m.
(2 hoses of 2.5 m to be divided into 4 hoses and 1 hose of
2.5 m to be divided into 4 hoses).
•
16 clamping strips.
•
4 grills: outer dimensions 35 cm × 20 cm, reserve dimensions
33 cm × 16.5 cm, with 2 connecting collars Ø150 mm.
•
Mantel iron: this must be sawn to the correct size.
•
felt roll to create an expansion joint between the metal of
the mantle iron and the surround.
The convection set can be ordered separately from Kalfire.
instead of a grating, openings (e.g. recessed plinths) can be used.
do not reduce the convection openings
place all grills/openings, top and bottom, to initiate natural
circulation. The grills/openings must be in the same room as
the fireplace.
Working method when using convection grills
ensure that, at the base, there is sufficient supply for the cold
convection air from the room at the top, connect the grills to the
outlet openings of the warm convection air (see Table 2).
Kalfire type
w45/48f
w53/50r
w60/51f
w65/38C
w66/48s
w80/52T
w90/47s
w71/62f
w85/40f
w90/47C
w70/33f
w100/61f
w105/47f
w105/47T
inlet of convection air
2× Ø150 mm
4× Ø150 mm
355 cm²
705 cm²
outlet of convection air
2× Ø150 mm
4× Ø150 mm
355 cm²
705 cm²
Table 2: Throughput openings for convection air
CAREFUL! place the gratings so that the flow is maintained
and cannot become clogged.
20