5.4.2 Rear flue connection of Kalfire W53/50R
The Kalfire w53/50r is standardly delivered with the flue exit
connection on the top of the appliance. This can be converted into
a rear connection, see appendix f.
5.4.3 Reducer ring
This fireplace is standardly delivered with a reducer ring
(excepting the Kalfire w53/50r) This ring can be used to connect
various flue systems to the Kalfire.
Kalfire type
Connecting collar (mm)
A
(mm)
B
(mm)
C
(mm)
w45/48f
Ø148 ±2
Ø156 ±1
Ø136 ±1
Ø152 ±1
w60/51f, w70/33f, w65/38C
Ø178 ±2
Ø186 ±1
Ø166 ±1
Ø182 ±1
w85/40f, w66/48s, w80/52T,
w53/50r
Ø198 ±2
Ø206 ±1
Ø186 ±1
Ø202 ±1
w53/50r, w71/62f, w90/47C,
w90/47s, w100/61f, w105/47f,
w105/47T
Ø248. ±2
Ø256 ±1
Ø236 ±1
Ø248. ±1
Table 4: diameter of chimney connecting collar
figure 22: reducer ring
an adapter ring is supplied with the Kalfire w65/38C and the
w90/47s models; this ring is slid onto the reducer ring. The
adapter ring for the Kalfire w65/38C is Ø180/ Ø200,
the reducer ring for the Kalfire w90/47s is Ø250/ Ø300. when
choosing the flue duct, bear in mind:
Kalfire W65/38C
Connection to a Ø200 flue duct is only possible with a chimney
duct of minimum 4.5 metres and maximum 6 metres long
Kalfire W90/47S
Connection to a Ø300 flue duct is only possible with a chimney
duct of a minimum 4.5 metres and a maximum 6 metres long.
5.5 Mounting the damper (optional)
The fireplace is standardly delivered without a damper. an
external damper can be used to influence the draught (suction)
in the flue. if there is too much suction in the flue, we advise you
to use a damper. You can test whether a damper is necessary
while checking the fireplace. pay extra attention to this aspect,
if the flue is longer than 7 metres. normally, the fireplace can be
controlled well using the secondary air regulation.
A
40
40
40
B
C
Points for attention:
•
Make sure that the position of the damper is visible for the
end user. for this purpose, most of the operating knobs
have a position indication (open = auf or +, Closed = Zu or -).
•
Check the functioning of the damper before completing the
installation of the fireplace.
•
Make sure that the end user is familiar with how the
damper functions.
24
Summary of Contents for W100/61F
Page 1: ...Installation and instructions Closed wood burning fireplaces DON T COMPROMISE EN ...
Page 2: ......
Page 4: ...4 ...