background image

 

 

 

16

 

 

The remote control measures the room temperature, allowing the strength of the fire to be 
adjusted accordingly. To ensure an accurate temperature reading, make sure the remote 
control is outside of the fire’s radiation range.  
 

 

Summary of Contents for GP75/59F

Page 1: ...User s guide Closed gas fire with Prestige burner English V11 2016_NL...

Page 2: ...GP75 59F GP80 55C GP85 55S GP105 59F GP110 55C GP115 55S GP105 79F GP110 75C GP115 75S GP60 59F GP65 55C GP70 55S GP60 79F GP65 75C GP70 75S GP80 54T GP85 50R...

Page 3: ...g the iMatch remote control 9 5 Using the LED lighting and NSG 17 6 NSG Natural Spark Generator 21 7 Using the iMatch interface via a smartphone or tablet 24 8 Troubleshooting 26 9 Maintenance 36 10 C...

Page 4: ...e installer should adhere to general installation and operation codes the provisions of urban planning regulatory authorities and national and European standards Key general usage instructions The fir...

Page 5: ...akage of smoke or fumes formation of carbon monoxide Switch off the gas fire immediately Shut off the gas valve Open the doors and windows Contact a certified installer If the flames are suddenly exti...

Page 6: ...n the door or if the glass has not yet been installed The heat generated by the fireplace s convection system can cause dust particles or the smoke from cigarettes candles or oil lamps to discolour wa...

Page 7: ...n the button on the remote control for around 10 seconds This emergency stop definitively cancels the heat controlling device pre empting automatic reignition 2 24 hour safety After 3 consecutive auto...

Page 8: ...cked code A08 In this case it is possible to use the remote control to try to unblock the fire a further 2 times before the system is locked for 24 hours lock out code F08 3 Overpressure safety device...

Page 9: ...action time so the fire may not respond instantaneously If the screen of the remote control illuminates after a button is pressed this indicates that the RF signal has been sent 4 1 Inserting the batt...

Page 10: ...g the signal 4 Indicates the height of the flame or the intensity of the lighting hybrid fire 5 Indicates that the fire is ignited if the symbol is flashing this indicates that a heating change or an...

Page 11: ...problem 10 Indicates that the fire is in thermostat mode 11 Indicates that the fire is in manual mode default mode A buttons and B left and right buttons C centre button D on off button E P parameter...

Page 12: ...ton The minutes will then begin to flash Use the or buttons to change the minutes then confirm the change by pressing 3 The number indicating the day of the week will then begin to flash Select the nu...

Page 13: ...WARM displayed at the top left of the screen begins to flash indicating that the request has been confirmed After several seconds a beep indicates that ignition is starting up and WAIT displays on th...

Page 14: ...ted and 1 the lowest flames 2 Use or to adjust the flame height as desired When the button is released the flame height is indicated by the number of horizontal bars The ECO mode has a modulating effe...

Page 15: ...consumption by around 40 To select this modulating effect use the remote control to set the flame height to 9 The double flame icon will display on the screen 4 7 Choosing between thermostat mode and...

Page 16: ...e control measures the room temperature allowing the strength of the fire to be adjusted accordingly To ensure an accurate temperature reading make sure the remote control is outside of the fire s rad...

Page 17: ...a number of ways to vary the lighting effects 5 1 Changing the LED lighting effects The different parameters controlling the LED lighting allow the oscillation intensity and colour to be set Select t...

Page 18: ...of the screen 3 Press to increase light intensity This button also serves to activate the LED lighting 4 Select to decrease light intensity This button also serves to deactivate the LED lighting The h...

Page 19: ...ing to the flame height as a result the higher the flames maximum setting the more sparks The default setting of the fire is SPo sparks off Once the fire is in use it saves the last programme selected...

Page 20: ...sparks per hour SP2 2 sprays of sparks per hour SP3 3 sprays of sparks per hour SP4 4 sprays of sparks per hour SP5 5 sprays of sparks per hour SP6 6 sprays of sparks per hour SP7 10 sprays of sparks...

Page 21: ...and on the NSG setting selected see Chapter 13 Refills of Natural Spark Powder are available from Kalfire A container of Natural Spark Powder completely fills the cartridge The opening to refill the N...

Page 22: ...80 55C GP90 55S Kalfire GP 105 59F GP110 55C GP115 55S Kalfire GP 105 79F GP110 75C GP115 75S At the right front of the hearth under a piece of ceramic charcoal Kalfire GP60 59F GP65 55C GP70 55S Kalf...

Page 23: ...packaging of the container of Natural Spark Powder Possible reasons for an absence of sparks If no sparks are generated this could be due to the following reasons The Natural Spark Powder cartridge i...

Page 24: ...ows the fire to be controlled via a smartphone or tablet application The application can be used with an iPhone iPad or Android smartphone and can be downloaded free from application download platform...

Page 25: ...25 6 Select configuration menu 7 Switch fire on or off 8 Select ECO mode 9 Add a fire...

Page 26: ...on indicated by E this type of malfunction is linked to communication problems between any of the printed circuit boards and the remote control They are resolved automatically by re establishing the r...

Page 27: ...used natural gas or propane butane In the case of natural gas the burner will make 3 automatic ignition attempts while in the case of propane butane it makes only 1 attempt If ignition fails the error...

Page 28: ...be tried Hold down the button until OK begins to flash at the top left of the screen 8 3 Unblocking the fire after a code F failure e g 08F After a period of 24 hours the burner will unlock automatica...

Page 29: ...h error codes Error code Cause Solution The batteries have run out Replace the batteries see section 12 1 NOLK 0 appears in the centre of the screen Control error no link Press until NOLK displays at...

Page 30: ...ll black button that you will need to push down at a later step Hold down the button on the remote control until NOLK 0 displays and then release the button if NOLK 1 displays select again until NOLK...

Page 31: ...ol and the fire If the indicator light on the burner control in the technical unit is not flashing Check the voltage in your home If the voltage is correct you should contact your installer in order t...

Page 32: ...k that there is no contact between the ionisation rod the symbol on the burner and the Kal Glow or the furnishings in the fire Check that the cable is correctly plugged into the technical unit see ion...

Page 33: ...is defective In either case contact your installer 08A Lack of ionisation detection during ignition If no flame is visible during ignition and no spark appears at the ignition rod the V symbol on the...

Page 34: ...r improperly connected to the burner or the ignition transformer may be defective 51A Disappearance of ionisation signal while the fire is operating Check the fire to ensure that there is no contact b...

Page 35: ...between the wifi router and the iMatch remote control is too great Position your wifi router and iMatch interface in the technical unit so they are closer together There is a configuration error in t...

Page 36: ...mmediately serviced Ask your installer about the possibility of a maintenance contract 9 2 Maintenance instructions The maintenance instructions can be downloaded using the QR code located next to the...

Page 37: ...a cleaning product for ceramic glass Do not use corrosive or abrasive products to clean any part of the fire Damage to the paint is not covered by the warranty Minor deterioration can be touched up w...

Page 38: ...d model the handles are located under the mantle and should be pulled gently upwards and outwards Step 3 Push in the metal protective strip at the left and right sides With a corner model just push in...

Page 39: ...efully and completely from the fire In a 3 sided model the glass falls slightly forwards and can be taken straight out of the groove 9 5 Replacing the glass To replace the glass follow the instruction...

Page 40: ...re using high quality materials If despite this any faults or defects should appear the following warranty terms are applicable 1 Before the installation of the fire the certified installer must ensur...

Page 41: ...right to compensation for the inability to use the gasfire 6 The repair or replacement of components covered by the warranty do not in any circumstances extend the total period of the warranty 7 If a...

Page 42: ...riod only in the Benelux countries Germany and France 11 In the case of an on site service visit outside of the warranty period all parts labour and travel expenses are to be paid by the customer The...

Page 43: ...med has been caused by external factors e g impact lightning flooding or dropping or overheating of the fire occurring during transport storage or mounting 8 If the fire has been handled or used incor...

Page 44: ...C Type Examination Certificate No E1398 5643 and comply with the essential requirements applicable to Directive 2009 142 GP75 59F GP80 55C GP85 55S GP105 59F GP110 55C GP115 55S GP105 79F GP110 75C GP...

Page 45: ...45 13 Wiring diagram...

Page 46: ...without the prior written consent of Kalfire Kalfire reserves the right to modify this guide Kalfire gives no guarantee implicit or explicit concerning the contents of this guide Any risks related to...

Page 47: ......

Page 48: ......

Reviews: