Kalfire Gi75/59F Installation Instructions Manual Download Page 6

 

1.3

 

Warranty 

Kalfire products are manufactured with 

meticulous precision from premium materials. 

Despite this, should an error or defect become 

apparent, Kalfire will provide warranty coverage 

according to the following provisions. 

 

Warranty conditions: 

1.

 

The warranty period for Kalfire gas 

appliances amounts to two years from the 

procurement date, that must be clearly 

legible on the proof of purchase. 

2.

 

The warranty period of 2 years does not 

apply to discolouration of the varnish on 

the flat or design; in this case a warranty 

period of 1 year applies. 

3.

 

Glass and rubber seals are excluded from 

the warranty. 

4.

 

Physical and chemical influences from 

outside during transport, storage or 

installation are not covered by the 

guarantee. 

5.

 

The gas fire must be installed by a 

technician approved by Kalfire according to 

this Installation Manual and in compliance 

with all relevant national and regional 

standards in force. 

6.

 

Kalfire assumes no responsibility for errors 

or defects related to the installation of the 

gas fire. Placing of the appliance, the 

quality and material choice of the finished 

product and a check as to the correct 

operation of the concentric flue duct 

system are the responsibility of the 

fireplace dealer approved by Kalfire. 

7.

 

The warranty covers no right whatsoever to 

compensation in the event that the 

appliance cannot be used. 

8.

 

Should disruption occur within the warranty 

period caused by a manufacturing error or 

material defect, Kalfire will deliver the 

components needed for repair to the 

installer of the gas fire, without paying 

compensation for dismantling or assembly. 

9.

 

Renewing or replacing components that fall 

under the scope of the guarantee do not 

extend the duration of the warranty. 

10.

 

Should the Kalfire-approved installer be 

unable to rectify the problem covered by 

the warranty, then he is entitled upon his 

own express desire to request Kalfire to 

assume responsibility for doing so (only 

valid in the Benelux, Germany, France and 

the United Kingdom). 

11.

 

Verification or repair of an entire gas fire or 

parts thereof can only take place by 

appointment, after prior consultation 

between Kalfire and the installer approved 

by Kalfire. 

12.

 

A dated proof of purchase must be 

presented to Kalfire should a possible 

home repair service (only available in the 

Benelux, Germany, France and the United 

Kingdom) be carried out within the 

warranty period. 

13.

 

In the event of home repair service outside 

the warranty period, material costs, working 

hours and call-out charges will apply. 

 

The warranty is not applicable in the following 

circumstances: 

1.

 

If the warranty provisions have not been 

complied with, in part or in full. 

2.

 

If alterations to the appliance have been 

brought about without Kalfire’s written 

permission to do so. 

3.

 

If the appliance passes into new ownership. 

4.

 

If the appliance has not been fitted 

according to the Installation Manual and/or 

has not been used according to the user 

instructions. 

5.

 

Should deviation from the Kalfire 

specifications have occurred in any way or 

form during installation of the concentric 

flue duct system. 

6.

 

Should deviation from the Kalfire 

specifications have occurred in any way or 

form during configuration of the decorative 

elements, including possible ceramic wood 

logs on the burner bed. 

7.

 

Damage attributable to external causes 

(shocks, lightning, falling, flooding or 

overheating of the appliance) during 

transport, storage or installation. 

8.

 

Should the appliance be impacted by 

neglect, improper use and/or gross 

negligence.  

9.

 

If the repair or delivery of individual parts 

be carried out by another manufacturer or 

by a professional technical fitter who has 

not been approved by Kalfire.  

 

Summary of Contents for Gi75/59F

Page 1: ...INSTALLATION INSTRUCTIONS Balanced flue gas systems...

Page 2: ......

Page 3: ...Balanced flue gas system Kalfire Gi Gi75 59F Gi80 55C Gi85 55S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S For gastype G20 G25 G30 en G31 Version 12_2023...

Page 4: ...ng and testing the gas fire 19 5 5 Gas measurement 19 5 6 Sustainability measurement 19 5 7 Placing the restriction plates 20 5 8 Removing the ceiling plates 20 5 9 Placing and finishing the surround...

Page 5: ...of whatever nature can also affect the safety of the gas fire Alterations can nullify the warranty and the technical testing and certification is no longer applicable If the gas fire is not installed...

Page 6: ...ould the Kalfire approved installer be unable to rectify the problem covered by the warranty then he is entitled upon his own express desire to request Kalfire to assume responsibility for doing so on...

Page 7: ...ce Kalfire accepts no liability for the failure of the Gi fireplace to function properly or at all due to causes described here 1 5 Receipt and verification Verification upon receipt The gas fire is d...

Page 8: ...iance with the directives in force NEN 1078 and NPR 3378 apply to The Netherlands NBN D51 003 chimney connection and gas connection applies to Belgium Arbeitsblatt G600 DVGW TRGI applies to Germany Ch...

Page 9: ...fire and the fireproof board material The materials used for the gas fire surround must be heat resistant and fireproof Under no circumstances must the gas fireplace be insulated Materials plaster and...

Page 10: ...Especially the glass can get extremely hot Children and dependants are to stay clear of the burning gas fire DANGER Make sure that flammable materials such as curtains and furniture are at least 100...

Page 11: ...rrupted for one minute A new ignition attempt follows automatically To interrupt automatic ignition attempts immediately Press the on off button max 2 sec to switch the fire off immediately A 24 hour...

Page 12: ...es in the fireplace and burn slowly Heat emission The heat generated by Kalfire gas fireplaces is directly emitted to the space in which the fireplace is located through radiation and convection Radia...

Page 13: ...through 6 paragraph 8 1 A chimney calculation is made for the roof pass through and the wall pass through The chimney calculation is suitable for gas types G20 G25 G30 and G31 Kalfire cannot guarantee...

Page 14: ...if all moving parts of the gas fire are functioning correctly principally the door before installing the fireplace 4 4 Check UTP connection and or WiFi signal For correct and stable operation of the f...

Page 15: ...o flexible duct should be connected directly to the appliance The first metre from the appliance must always be carried out with a fixed pipe After the first metre the inner pipe flue may be made with...

Page 16: ...gas fire need to be precisely sawn off before they can be mounted When the bolts are mounted against the rear wall a space of a minimum of two cm is created between the rear side of the appliance and...

Page 17: ...nstallation Instructions paragraph 2 3 5 At the front leave a minimum of 1 mm of space between the glass support and the finishing Prevent excessive tension on the glass caused by the glass support as...

Page 18: ...ected app which can be downloaded from the Apple or Google app store TIP Check the strength of the wifi signal near the fireplace If necessary place a wifi amplifier near the fireplace to ensure a str...

Page 19: ...entification plate indicates which type of gas the appliance is set for The id plate is located on the left side of the cooling slot on a metal plate It can be tilted upwards see figure 16 To do this...

Page 20: ...late is supplied as standard with every fireplace Figure 18 Restriction plate assembly in the flue Carry out the following steps to place the restriction plate 1 Remove the door See Door dismantling a...

Page 21: ...necting with convection hood The convection hood is mounted on the appliance in the factory and so cannot be installed afterwards The convection hood ensures a delivery of controlled heat in the room...

Page 22: ...ording to the instructions It is prohibited to alter the number of decorative elements or the configuration thereof Such alterations can lead to hazardous situations with regard to fire safety Take th...

Page 23: ...airing takes place If automatic pairing does not take place proceed as follows You easily check whether the fireplace is paired by operating button 8 EmberGlow of the remote control see image below If...

Page 24: ...h consists of 5 levels The higher the level the more LEDs in the KalSense ring light up brightly In the KalfireConnected app the KalSense ring is also displayed on the screen This corresponds to the K...

Page 25: ...run mode the fireplace is on press button 1 x do not hold to switch off the fireplace The KalSense ring lights up briefly Comfort function Moves to the last used comfort plus setting KalSense feedback...

Page 26: ...han the remote control Besides controlling the various functions the temperature can be read and programmed for the thermostat and Comfort function via this app Furthermore 10 Moods can be programmed...

Page 27: ...g instructions anti reflective glass The gas fire glass can become dirty when the fireplace is burning but also when being taken into use Potential causes can be Smoking materials in the fireplace esp...

Page 28: ...the handles under the hood towards you and up Step 2 Push the metal cover strip in left or right Step 3 Next grip the door by the designated handles Slightly lift the door with glass window out of th...

Page 29: ...cover strip down 7 3 Replacing batteries If the red LED on the top right of the remote control no longer lights up if you press any of the buttons the battery needs to be replaced Replace the battery...

Page 30: ...tion 1 Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200mm 1st metre vertical...

Page 31: ...5S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm 1st metre vertical min 1 m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90...

Page 32: ...59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90 Remove the ce...

Page 33: ...9F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90 Horizontal sect...

Page 34: ...S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1st metre vertical min 1 m Vertical elbow 90 Remove the ceiling plate 3 3 Vertica...

Page 35: ...0 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m 1e meter verticaal min 0 5m Vertical elbow 90 Horizontal section ma...

Page 36: ...110 75C Gi115 75S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Elbow 15 30 of 45 Diagonal section...

Page 37: ...5S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Elbow 15 30 of 45 Diagonal section Elbow 15 30 of...

Page 38: ...75S Gi105 59F Gi110 55C Gi115 55S Gi105 79F Gi110 75C Gi115 75S Gas type G20 G25 G30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Connector 130 200 100 150 C Elbow 15 30 of 45 Dia...

Page 39: ...30 G31 Flue duct diameter 130 200 mm Max vertical length m 12 m 12 m Situation 1 Connector 130 200 100 150 C n a n a Min 1 m Max 2 m vertical 130 200 Roof pass through B Situation 2 Min 2 m Max 4 m ve...

Page 40: ...sure sensor hotel switch Safety Contact 5 6 The Gi checks the status of this input it must be closed before the start of the ignition cycle and during the operational status of the Gi If it is opened...

Page 41: ...77 1 79 1 71 7 G30 50mbar C 7 3 1 8 77 1 79 1 71 7 G31 37 mbar D 6 1 1 5 73 5 75 9 65 4 Kalfire Gi105 59F Kalfire Gi105 79F Kalfire Gi110 55C Kalfire Gi110 75C Kalfire Gi115 55S Kalfire Gi115 75S G25...

Page 42: ...82 77 1 G31 37 mbar C 6 4 1 6 79 81 2 70 5 Kalfire Gi105 59F Kalfire Gi105 79F Kalfire Gi110 55C Kalfire Gi110 75C Kalfire Gi115 55S Kalfire Gi115 75S G25 3 B 7 4 2 2 86 6 88 5 84 5 G20 B 7 5 2 4 86 8...

Page 43: ...e detection no room temperature control with open window detection no with distance control option yes with adaptive start control no with working time limitation no with black bulb sensor no Indirect...

Page 44: ...uations with regard to fire safety Take the instructions into account Safety instructions for decorative elements paragraph 2 4 Artikel nr Artikel omschrijving Aantal 1 550057 Cover log F060683 1 2 55...

Page 45: ...45...

Page 46: ...46...

Page 47: ...47...

Page 48: ...nstructions into account Safety instructions for decorative elements paragraph 2 4 Article nr Article description Number 1 550129 Burner cover Gi KF03661 1 2 550132 Deco plate back Gi KF03655 1 3 5501...

Page 49: ...49...

Page 50: ...50...

Page 51: ...51...

Page 52: ...52...

Page 53: ...53...

Page 54: ...54...

Page 55: ...I3B P G30 28 30 9 2 0 28 2x 1 0 1 4 11 3 4 1 7 3 79 1 C C 73 I3B P G30 50 9 2 0 28 2x 1 0 1 4 11 3 4 1 7 3 79 1 C C 73 KALFIRE Gi105 59F Gi110 55C Gi115 55S Gas cat Gas type Connection pressure Load...

Page 56: ...K G25 3 25 8 5 1 02 2x 1 6 1 8 19 4 7 1 6 8 81 1 C B 69 I2ELL G20 G25 20 8 7 0 92 2x 1 6 1 8 15 5 6 5 6 9 79 7 C B 83 I3 G31 37 7 1 0 29 2x 1 0 1 4 14 7 4 2 5 6 78 6 C B 65 I3 G30 28 30 9 1 0 28 2x 1...

Page 57: ...G30 28 30 mbar I3B P G30 50 mbar LB LT LU LV MT NL NO NZ PL PT RO RU SE SI SK TN UA I2H G20 20 mbar I2E G20 20 mbar I2E G20 G25 20 25 mbar I2 43 46 45 3 MJ m3 0 C I2K G25 3 25 mbar I2ELL G20 G25 20 m...

Page 58: ...F Gi110 75C Gi115 75S This declaration of conformity complies with the Harmonisation legislation of the Union Directive 2009 142 EC Regulation EU 2016 426 of 21 April 2018 Directive 2009 125 EC Regula...

Page 59: ...59...

Page 60: ...Gelo rveldweg 21 5951 DH Belfeld info kalfire com KALFIRE COM V12 2023 EN...

Reviews: