35
A.1 Product card (in conformance with (EU) 2015/1186 Appendix IV)
*the values in this table are inspection values in line with EN613, measured with a short configuration.
Model
Gas t
ype
En
er
gy
efficie
ncy class (k
c)*
Dir
ec
t
he
at ou
tpu
t
Indir
ec
t
he
at ou
tpu
t
En
er
gy efficie
ncy
ind
ex (EEI)
Useful r
et
urn at
nominal h
eat ou
tpu
t
Useful r
et
urn at
minimum h
eat ou
tpu
t
Kalfire G60/48F
Kalfire G65/44C
Kalfire G70/44S
G25
C
6.0 kW
n/a
81%
84.0%
74.3%
Kalfire G60/48F
Kalfire G65/44C
Kalfire G70/44S
G20
C
5.8 kW
n/a
82%
85.3%
80.0%
Kalfire G60/48F
Kalfire G65/44C
Kalfire G70/44S
G30 - 30 mbar
D
5.5 kW
n/a
72%
75.3%
68.3%
Kalfire G60/48F
Kalfire G65/44C
Kalfire G70/44S
G30 - 50 mbar
D
5.6 kW
n/a
72%
75.7%
67.8%
Kalfire G80/48F
Kalfire G85/44C
Kalfire G90/44S
G25
C
6.8 kW
n/a
79%
82.3%
77.2%
Kalfire G80/48F
Kalfire G85/44C
Kalfire G90/44S
G20
C
6.6 kW
n/a
79%
82.6%
78.4%
Kalfire G80/48F
Kalfire G85/44C
Kalfire G90/44S
G30 - 30 mbar
D
5.1 kW
n/a
75%
78.3%
49.4%
Kalfire G80/48F
Kalfire G85/44C
Kalfire G90/44S
G30 - 50 mbar
D
5.1 kW
n/a
75%
78.3%
49.4%
Kalfire G100/41F
Kalfire G105/37C
Kalfire G110/37S
G25
D
7.4 kW
n/a
74%
77.4%
64.2%
Kalfire G100/41F
Kalfire G105/37C
Kalfire G110/37S
G20
C
7.4 kW
n/a
80%
83.2%
79.8%
Kalfire G100/41
Kalfire G105/37C
Kalfire G110/37S
G30 - 30 mbar
D
8.2 kW
n/a
72%
75.4%
61.6%
Kalfire G100/41F
Kalfire G105/37C
Kalfire G110/37S
G30 - 50 mbar
D
9.8 kW
n/a
73%
75.8%
69.6%
Kalfire G120/41F
Kalfire G125/37C
Kalfire G130/37S
G25
C
8.8 kW
n/a
81%
83.8%
86.1%
Kalfire G120/41F
Kalfire G125/37C
Kalfire G130/37S
G20
C
8.3 kW
n/a
81%
84.6%
76.4%
Kalfire G120/41F
Kalfire G125/37C
Kalfire G130/37S
G30 - 30 mbar
C
9.7 kW
n/a
81%
76.5%
73.6%
Kalfire G120/41F
Kalfire G125/37C
Kalfire G130/37S
G30 - 50 mbar
D
9.9 kW
n/a
76%
78.9%
62.7%
Kalfire G160/41F
Kalfire G165/37C
Kalfire G170/37S
G25
C
10.4 kW
n/a
79%
78.9%
70.1%
Kalfire G160/41F
Kalfire G165/37C
Kalfire G170/37S
G20
C
10,8 kW
n/a
81%
81.8%
77.8%
Kalfire G160/41F
Kalfire G165/37C
Kalfire G170/37S
G30 - 30 mbar
C
11.0 kW
n/a
79%
83.8%
77.0%
Kalfire G160/41F
Kalfire G165/37C
Kalfire G170/37S
G30 - 50 mbar
C
11.3 kW
n/a
79%
82.0%
79.6%
Kalfire GP60/59F
Kalfire GP65/55C
Kalfire GP70/55S
G25
D
6.2 kW
n/a
72%
76.1%
62.7%
Kalfire GP60/59F
Kalfire GP65/55C
Kalfire GP70/55S
G20
D
6.1 kW
n/a
72%
76.0%
66.7%
Kalfire GP60/59F
Kalfire GP65/55C
Kalfire GP70/55S
G30 - 30 mbar
D
7.6 kW
n/a
72%
76.1%
65.9%
Kalfire GP60/59F
Kalfire GP65/55C
Kalfire GP70/55S
G30 - 50 mbar
D
7.6 kW
n/a
72%
76.1%
65.9%
Kalfire GP60/79F
Kalfire GP65/75C
Kalfire GP70/75S
G25
D
7.8 kW
n/a
73%
76.3%
66.2%
Kalfire GP60/79F
Kalfire GP65/75C
Kalfire GP70/75S
G20
D
7.9 kW
n/a
72%
76.2%
67.4%
Kalfire GP60/79F
Kalfire GP65/75C
Kalfire GP70/75S
G30 - 30 mbar
D
7.9 kW
n/a
73%
76.8%
70.6%
Kalfire GP60/79F
Kalfire GP65/75C
Kalfire GP70/75S
G30 - 50 mbar
D
7.9 kW
n/a
73%
76.8%
66.2%
Kalfire GP75/59F
Kalfire GP80/55C
Kalfire GP85/55S
G25
D
8.0 kW
n/a
73%
77.0%
78.3%
Kalfire GP75/59F
Kalfire GP80/55C
Kalfire GP85/55S
G20
C
8.7 kW
n/a
79%
83.0%
64.6%
Kalfire GP75/59F
Kalfire GP80/55C
Kalfire GP85/55S
G30 - 30 mbar
D
4.2 kW
n/a
73%
77.4%
64.6%
Kalfire GP75/59F
Kalfire GP80/55C
Kalfire GP85/55S
G30 - 50 mbar
D
4.7 kW
n/a
73%
77.4%
77.8%
Kalfire GP105/59F
Kalfire GP110/55C
Kalfire GP115/55S
G25
D
7.7 kW
n/a
73%
77.0%
68.2%
Kalfire GP105/59F
Kalfire GP110/55C
Kalfire GP115/55S
G20
C
8.8 kW
n/a
78%
82.0%
78.7%
Kalfire GP105/59F
Kalfire GP110/55C
Kalfire GP115/55S
G30 - 30 mbar
D
4.5 kW
n/a
73%
77.4%
67.7%
Kalfire GP105/59F
Kalfire GP110/55C
Kalfire GP115/55S
G30 - 50 mbar
D
4.6 kW
n/a
73%
77.4%
67.7%
Kalfire GP105/79F
Kalfire GP110/75C
Kalfire GP115/75S
G25
C
10.3 kW
n/a
77%
80.7%
78.6%
Kalfire GP105/79F
Kalfire GP110/75C
Kalfire GP115/75S
G20
C
11.4 kW
n/a
79%
82.1%
74.1%
Kalfire GP80/54T
Kalfire GP85/50R
G25
D
7.7 kW
n/a
73%
77.0%
71.3%
Kalfire GP80/54T
Kalfire GP85/50R
G20
D
7.9 kW
n/a
75%
79.0%
75.1%
Kalfire GP80/54T
Kalfire GP85/50R
G30 - 30 mbar
D
6.1 kW
n/a
73%
77.1%
69.6%
Kalfire GP80/54T
Kalfire GP85/50R
G30 - 50 mbar
D
6.1 kW
n/a
73%
77.1%
69.6%
Summary of Contents for G Series
Page 1: ...User instructions BALANCED FLUE GAS FIRES DON T COMPROMISE EN...
Page 2: ......
Page 4: ......
Page 6: ...6...
Page 38: ...38...
Page 39: ...39...
Page 40: ...Gelo rveldweg 21 5951 DH Belfeld info kal fire nl KALFIRE COM DON T COMPROMISE REF V01 2019 EN...