1. Scope of supply

  

Lamp 

Reflector,  

Removable 

Desktop 

Energy saving lamp  

  

Holder 

ø 27 cm, 

(10.6 in.)

 

diffusion cover 

stand 

25 W, 6400 K   

5860   Lamp Holder 

1 x 

 

 

 

 

5861   Desktop Lighting Kit 1 

1 x  

1 x  

1 x  

1 x 

1 x 

5862   Desktop Lighting Kit 2* 

2 x  

2 x  

2 x  

2 x  

2 x 

3140   Studio Light 

1 x  

1 x  

1 x  

 

 

*also included in the Desktop Shooting Kits 5863 and 5864

2. Putting into operation

Do not connect the lamp holder (5) to the mains yet. 
The lamp holder has to be mounted on a light stand (4) (Fig. 
A) or a mounting system with a 16 mm standard spigot (3) 
(light stand(s) are included with 5861-62). Loosen the locking 
screw (6), fit the lamp holder and tighten the locking screw (6).
Attach the reflector (8) (supplied with 3140 and 5861-62) to 
the lamp holder (5) (Fig. B).
Screw a suitable lamp (max. 250 W) into the ceramic socket 
(9). See section 7 for suitable lamps. 
Make sure that the mains voltage corresponds to the ope-
rating voltage given on the type plate (7) of the light. Then 
connect the light to the mains.
The light is switched on/off with switch (1).
The light can be used for unlimited continuous operation. 
  

3. Tilting and height adjusting  

 

At first let the light (lamp holder, lamp, reflector (if fitted)) cool 
down.
To tilt the light loosen the locking screw (6), move the light 
into the required position (Fig. C) and tighten the screw again.
5861-62: To adjust the height of the stand, loosen the locking 
screw (11) respectively (12) (Fig. D). Before doing so, hold up 
the light to prevent it from moving downwards due to its own 
weight. Tighten the locking screw again. 

4. Diffusing cover and umbrella mount 

The heat-resistant diffusing cover (13) (supplied with 3140 
and 5861-62) can be used to achieve a softer illumination 
(Fig. E).
A reflector umbrella or shoot-trough umbrella (Fig. F) can be 
attached with the umbrella mount (2). The reflector (8) (sup-
plied with 3140 and 5861-62) has an opening (10) for the 
umbrella rod allowing to attach an umbrella with a mounted 
reflector. When attaching the reflector the opening (10) should 
be on the bottom.   

5. Important notes  

 

Use the light with care, e.g. avoid wrong voltages or connec-
tion to equipment not specifically designed for this type of 
light. Use lamps with max. 250 W. If these precautions are not 
observed, the light may be damaged and in extreme cases 
the lamp may burst. 
Make sure that the light is not covered and keep away at least 
0.5 m (20 in.) from heat-sensitive substances in direction of 
light during operation. 
Avoid touching the light (lamp holder, lamp, reflector) when 
the light is on. Let the light cool down after use.
The light may only be serviced by qualified persons. 
 

Do not expose the mains cable to excessive physical 
strain. 

6. Maintenance and care  

The light requires no maintenance. Make sure that the reflec-
tor (8) (with 3140, 5861-62) is free of marks and foreign bo-
dies. If necessary remove them before use. Clean the housing 
of the light only with a soft dry cloth. On no account use pet-
rol or other cleaning agents and solvents.  

 

 

7. Accessories 

Suitable lamp for lamp holder 5860:
3128*  Reflector lamp 150 W, 3200 K

Suitable lamps for lamp holder 5860 with attached reflector 
(with or without diffusion cover):  

 

3110  Energy saving lamp 25 W, 6400 K  
4356  Opal lamp 75 W, 3000 K  

 

3124  Opal lamp 150 W, 3000 K  

 

3130*  Photoflood 250 W, 3000 K  

 

3128*  Reflector lamp 150 W, 3200 K

*not available in 120 V version

8. Specifications

Operating voltage:   AC 230 – 240 V, 50 Hz or  

 

  

AC 120 V, 60 Hz (see type plate) 

Socket:  

E 27 (120 V: E 26)  

Lamps fitted 

  

(per lamp holder):   250 W max.   
Cable length: 

approx. 3.80 m (12.5 ft.)  

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Right reserved to make technical modifications. 

5862_Bed_0313.indd   4

28.03.13   10:04

Summary of Contents for 5860

Page 1: ...1 Desktop Beleuchtungs Set 1 5862 Desktop Beleuchtungs Set 2 3140 Studioleuchte Bedienungsanleitung Operating Instructions Mode d emploi Modo de empleo Istruzioni per l uso 5860 5861 5862 3140 5862_Be...

Page 2: ...B C 7 13 D E F 6 6 2 A 1 2 3 4 5 4 12 11 8 5 9 10 5862_Bed_0313 indd 2 28 03 13 10 04...

Page 3: ...t 5 Sicherheitshinweise Vermeiden Sie unsachgem en Gebrauch der Leuchte z B bei berspannung oder in Verbindung mit Ausr stungsteilen die nicht speziell f r diesen Leuchtentyp ausgelegt sind Ver wenden...

Page 4: ...ector umbrella or shoot trough umbrella Fig F can be attached with the umbrella mount 2 The reflector 8 sup plied with 3140 and 5861 62 has an opening 10 for the umbrella rod allowing to attach an umb...

Page 5: ...irage avec pr caution exemple viter les mauvaises tensions ou mauvais branchements ou tout quipement non conforme avec ce type d clairage Utilisez des lampes de 250 W maximum Si ces instructions ne so...

Page 6: ...o voltajes equivocados o conexiones a equipos no dise ados espec ficamente para este tipo de l mparas Use bombillas de un m ximo de 250 W Si no se observan estas precauciones la l mpara se podr a da a...

Page 7: ...tare voltaggi non corretti o collegamenti allo strumento non specificamente adatti a questo tipo di illuminatore Usare lampade con una Poten za massima di 250 W Se non vengono osservate queste precauz...

Page 8: ...GmbH Co KG Im Kr tenteich 2 74722 Buchen Germany Telefon 49 0 6281 407 0 Fax 49 0 6281 407 55 www kaiser fototechnik de info kaiser fototechnik de Printed in Germany 0313 000586000900 5862_Bed_0313 in...

Reviews: