The indoor unit should be installed in an indoor water proof place, or the safety of the unit and the operator cannot be
ensured.
CAUTION
The indoor unit is to be wall mounted in an indoor location that meets the following requirements:
The installation location is frost-free.
The space around the unit is adequate for serving, see figure 4-4.
The space around the unit allows for sufficient air circulation.
There is a provision for condensate drain and pressure relief valve blow-off.
When the unit running in the cooling mode, condensate may drop from the water inlet and water outlet pipes. Please make
sure the dropping condensate will not result in damage of your furniture and other devices.
CAUTION
The installation surface is a flat and vertical non-combustible wall, capable of supporting the operation weight of the unit.
All piping lengths and distance have been taken into consideration.
Requirement
Maximum allowable piping length between the 3-way valve SV1 and the indoor unit
(only for installations with domestic hot water tank)
Maximum allowable piping length between the domestic hot water tank and the indoor unit
(only for installations with domestic hot water tank). The temperature sensor cable supplied
with the indoor unit is 10m in length.
Table 3-1
Maximum allowable piping length between the TW2 and the indoor unit. The temperature
sensor a cable of TW2 supplied with the indoor unit is 10m in length.
3m
8m
8m
Value
10
4.1 Dimensions
4 INSTALLATION PRECAUTIONS
4.2 Installation requirements
40
158
158
3× 12
Fig.4-1
The indoor unit is packed in a box.
At delivery, the unit must be checked and any damage must be reported immediately to the carrier claims agent.
Check if all indoor unit accessories are enclosed.
Bring the unit as close as possible to the final installation position in its original package in order to prevent damage
The indoor unit weight is approximately 50kg and should be lifted by two persons.
Dimensions of the wall bracket:
NO.
1
2
3
4
5
NAME
Refrigerant gas connection5/8"-14UNF
Refrigerant liquid connection 1/4"(60) or 3/8"(100/160) -14UNF
Drainage 25
Water Inlet R1”
Water Outlet R1”
Refrigerant gas connection 5/8"-14UNF
Dimensions of the unit:
Fig.4-2
during transport.
unit:mm
unit:mm
1
23
4
5
40
50
152
824 790
721
53
149
158
158
60
49
82
151
68
216
87
86