Page 25
Indoor Unit
Installation
Step 6: Connect drain hose
The drainpipe is used to drain water away from
the unit. Improper installation may cause unit
and property damage.
NOTE ON PURCHASING PIPES
Installation requires a polyethylene tube
(exterior diameter = 3.7-3.9cm, interior
diameter = 3.2cm), which can be obtained at
your localhardware store or dealer.
1.
2.
Drainpipe
connecting port
Drain hose
Pipe clasp
Insulation
Cover the drainpipe with heat insulation to
prevent condensation and leakage.
Attach the mouth of the drain hose to the
unit’s outlet pipe. Sheath the mouth of the
hose and clip it firmly with a pipe clasp.
Lean over 1/100
•
Insulate all piping to prevent condensation,
which could lead to water damage.
•
If the drainpipe is bent or installed
incorrectly, water may leak and cause a
water-level switch malfunction.
•
In HEAT mode, the outdoor unit will
discharge water. Ensure that the drain hose
is placed in an appropriate area to avoid
water damage and slippage.
•
DO NOT
pull the drainpipe forcefully. This
could disconnect it.
CAUTION
NOTE ON DRAINPIPE INSTALLATION
•
When using an extended drainpipe, tighten
the indoor connection with an additional
protection tube. This prevents it from
pulling loose.
•
The drainpipe should slope downward at a
gradient of at least 1/100 to prevent water
from flowing back into the air conditioner.
•
NOTE:
When connecting multiple drainpipes,
install the pipes as illustrated.
Incorrect installation could cause water to
flow back into the unit and flood.
≥
10cm
(4”)
In order to ensure smooth drainage, the height
difference between the wall outlet and the
hanging plate must be greater than 470mm.
Drainage pipe fixing requirements
When installing the drainage pipe (not provided ),
please fix it with a tie or rope.
470mm
Recommended opening location
of connecting pipe outlet
φ55