Troubleshooting 8
4. Information Inquiry&Setting
• To enter engineer mode, in power-on or standby mode, and in non-locked state, press the key combination “ON/OFF
+ Air Speed” for 7s:
• After entering the engineer mode, the remote control will display icons of “Auto, Cool, Dry, Heat”, and the Battery
icon; at the same time, it will also display the numeric code of the current engineer mode (for the initial engineer
mode, the numeric code displayed is 0), and all other icons are inactive.
• In engineer mode, the value of the current numeric code can be adjusted circularly through the Up/Down key, with
the setting range of 0 to 30. Each time the current numeric code is adjusted, the special code of the engineer mode
will be transmitted with a delay of 0.6s. The code can also be transmitted by pressing “OK”, and the special code of
the engineer mode sent contains information of the currently displayed numeric code (if the numeric code is 0, the
code to enter the engineer mode will be transmitted).
• In engineer mode, other keys or operations are invalid except for the On/Off key, the Up/Down key, the OK key or
executing the operation to exit the engineer mode.
Code
Query Content
Advanced Function Setting
0
Error code
/
1
T1 temperature
press "On/Off" for 2s to enter the Power Down Memory Selector, the code
displayed is “Ch”, press "OK" to send the Query Power Down Memory
Selector code; press the Up/Down key to select 1 or 0 and press “OK” to
confirm, 1 indicates that the power down memory exists, and 0 indicates that
no power down memory exists; and press "On/Off" for 2s to exit. (Set within
1 minute after power on)
2
T2 temperature
press "On/Off" for 2s to enter the Internal Fan Control Selector after the pre-
set temperature is reaches, the code displayed is “Ch”, press "OK" to send
the Query Internal Fan Control Selector code; press the Up/Down key to select
1 to 11: 1 - Stop the fan, 2 - Min. air speed, 3 - Set the air speed, 4 - Termal
stop for 4min running for 1min, 5 - Termal stop for 8min running for 1min, 6 -
Termal stop for 16min running for 1min, 7 - Termal stop for 24min running for
1min, 8 - Termal stop for 48min running for 1min, 9 - Termal stop for 15min
running for 2.5min, 10 - Termal stop for 30min running for 2.5min and 11 -
Termal stop for 60min running for 2.5min, press "OK" to confirm, and press
"On/Off" for 2s to exit.(Item 5~11 are valid for some models)(Set within 1
minute after power on)
3
T3 temperature
press "On/Off" for 2s to enter the Mode Selector, press the Up/Down key to
select CH (cool and heat, Auto + Cool + Dry + Heat + Fan), HH (Heat only,
Heat only + Fan), CC(Cool only, Auto + Cool + Dry + Fa) or nU (Cool and
Heat without Auto, Cool + Dry + Heat + Fan), press "OK" to confirm, and the
mode selected can be memorized when the remote control is powered down
and powered on; and press "On/Off" for 2s to exit. When the remote control
does not burn any parameters, the mode setting will not be memorized.(CC or
nU is valid for some models)(Set within 1 minute after power on)
4
T4 temperature
press the "On/Off" for 2s to enter the Min. Set Temperature Selector, press
the Up/Down key to select "16°C~24°C", press "OK" to confirm, and the
Min. Set Temperature can be memorized when the remote control is powered
on and power lost; and press "On/Off" for 2s to exit. When the remote
control does not burn any parameters, the min. set temperature will not be
memorized.(Set within 1 minute after power on)
Summary of Contents for ICE Series
Page 1: ...SPLIT TYPE AIR CONDITIONER Service Manual ICE series...
Page 2: ......
Page 5: ...Contents 1 Precautions 2 2 Information servicing For flammable materials 3 Safety Precautions...
Page 17: ......
Page 19: ...Outdoor unit wiring diagram 16022000019533...
Page 20: ......
Page 21: ...Outdoor unit printed circuit board diagram 17122000048121 17122000046453...
Page 61: ...Outdoor Unit Disassembly 3 2 Dimension 2 1 Panel Plate X130...
Page 62: ...Outdoor Unit Disassembly 4 For US models Rounded grille...
Page 63: ...Outdoor Unit Disassembly 5 2 2 Panel Plate X230...
Page 64: ...Outdoor Unit Disassembly 6 For US models Rounded grille...
Page 65: ...Outdoor Unit Disassembly 7 For US models Square grille...
Page 66: ...Outdoor Unit Disassembly 8 2 3 Panel Plate X330...
Page 67: ...Outdoor Unit Disassembly 9 For US models Rounded grille...
Page 68: ...Outdoor Unit Disassembly 10 For US models Square grille...
Page 69: ...Outdoor Unit Disassembly 11 2 4 Panel Plate X430...
Page 70: ...Outdoor Unit Disassembly 12 For US models Rounded grille...
Page 71: ...Outdoor Unit Disassembly 13 For US models Square grille...
Page 72: ...Outdoor Unit Disassembly 14 2 5 Panel Plate D30...
Page 73: ...Outdoor Unit Disassembly 15 For US models...
Page 122: ...Troubleshooting 15...
Page 167: ......
Page 168: ...kaisai com...