7.  Re-attach the top plate, 

as follows

a.  Position the top plate on the frame. 
b.  Apply Loctite to the twelve (12) screws removed in step 2.a. 
c.  Use a #2 Phillips driver, the Loctited screws, and the twelve (12) lock 

washers removed in step 2.a. to secure the top plate to the frame. 

 

 

Summary of Contents for Pronto4

Page 1: ...3 16 41 Pronto4 Mounting Feet MLT Field Installation 01_00_01 doc Pronto4 Mounting Feet MLT Field Installation 1 Note and photograph relative servo and multifunction module locations 2 Remove the servo and multifunction modules as follows a Use an 8 32 hex driver to remove each of the four 4 outermost corner screws Set screws aside for reinstallation b Carefully pull out the module c Repeat 2 a an...

Page 2: ... 6 2014 06 03 16 41 Pronto4 Mounting Feet MLT Field Installation 01_00_01 doc 3 Remove the top plate as follows a Use a 2 Phillips driver to remove all twelve 12 screws and lock washers from the top plate Set screws aside for reinstallation b Manually remove the top plate Set top plate aside for reinstallation 4 Remove the current feet as follows a Use a pair of needle nose or bent nose pliers to ...

Page 3: ...16 41 Pronto4 Mounting Feet MLT Field Installation 01_00_01 doc b Use a 2 Phillips driver and an 11 32 socket and driver to remove the lock washer and screw from each foot 5 Attach the Pronto4 Mounting Feet Assembly p n MCA 00129 as follows a Use a 2 Phillips driver to drive a screw through a foot and into the frame with at least a few threads visible inside the frame b Use a 2 Phillips driver and...

Page 4: ...the servo and multifunction modules as follows WARNING Using the notes and photographs taken in step 1 ensure each module is placed into the correct bay Failure to do so will result in unpredictable behavior and may cause system damage WARNING If the module connector and interior frame connector are not adequately aligned then damage can be done to the connector pins If damage is done to the pins ...

Page 5: ...e s faceplate should be evenly flush with the frame Immediately stop if there is any pressure while connecting the module or if the faceplate is not evenly flush to the frame Pull the unit back realign it and try again Repeat until the module is connected without pressure d Apply Loctite 248 or other anaerobic threadlocking adhesive to four 4 of the screws removed during step 2 a e Use an 8 32 hex...

Page 6: ...ing Feet MLT Field Installation v 01 00 01 Page 6 of 6 2014 06 03 16 41 Pronto4 Mounting Feet MLT Field Installation 01_00_01 doc 7 Re attach the top plate as follows a Position the top plate on the frame b Apply Loctite to the twelve 12 screws removed in step 2 a c Use a 2 Phillips driver the Loctited screws and the twelve 12 lock washers removed in step 2 a to secure the top plate to the frame ...