1 0
The coolant container must be filed 3/4 of its total volume with coolant. Subsequently, the
pump must be vented.
The minimum filing height is the upper edge of the pump.
The coolant equipment is connection to the machine by means of the blue electrical
socket. To vent the pump, open the pump vent screw.
The coolant pistol is used to clean the machine, as well as to clean work pieces. The
pistol only functions when the coolant pump is in operation. This must be actuated in
manual operation using the F8 key, respectively it can also be switched off with the F8
key.
Basic information regarding cooling lubricants:
Please only use water-miscrible emulsions on a mineral oil basis. Synthetic products can
cause serious damage to the paint coating. We do not accept any liability for such
damages.
When testing cooling lubricants, please observe the provisions of the respective
manufacturer. Please also observe the respective disposal regulations.
Electrical socket for coolant equipment
Nozzle adjustment by means of turning
Setting of the amount of fluid