FK Range - Coffee dispensers
- 13 -
Concentrate sensors
This function enables or disables the Liquid coffee sensor/s
Press
button
Display shows:-
Product sensors
Enabled / disabled
Use
or
buttons to select sensor operation
Boiler temperature calibration
This function is used to calibrate the temperature and match the temperature
displayed on the display to the actual temperature of the boiler when read from a
thermometer placed in the water tank.
Press
button
Display shows:-
Calibrate temp
XX°C/F
Use
or
buttons to change the reading on the display to the actual water
temperature; this should be carried out 10 minutes after the heater elements have
turned off, to allow for convection currents in the tank to settle down.
Resetting dispense counters
This function is used to clear the selection counters.
Press
button
Display shows:-
Clear Totals
Press a selection button to clear the stored dispense totals.
Show the boiler temperature on the display
Press
button,
Display shows:-
Temp display
Celsius
Use
or
buttons to select Celsius, Fahrenheit or None