WIRING DIAGRAM

Model TF 210E - 460 VAC

Sheet 2 of 2

OPTIONAL DR

AIN

Dr

ain A

lar

m #2 I

nput

13

21

W36

W28

W37

W34

W32

W30

FMD #1 I

n (RJ-11)

FMD #2 I

n (RJ-11)

J2 RS

-232

RED

BLA

CK

WHITE

22

21

20

19

18

17

16

15

14

W38

Ev

apor

at

or T

her

mist

or

Ev

apor

at

or T

her

mist

or

Phase B xfmr I

nput

Phase A xfmr I

nput

Phase C

om. xfmr I

nput

W4

N/A

N/A

W7

W6

W5

N/A

W35

Gnd

. (

W28 thru 

W32)

Remot

e/L

ocal I

nput

Remot S

tar

t/S

top I

nput

N/A

N/A

W33

W31

N/A

N/A

N/A

W29

W12

30

37

35

36

34

35

34

33

32

31

TC

I

TB2

TB2

25

29

28

27

26

28

27

26

24

23

22

23

22

TB2

28

26

27

EMM INSTRUMENT BO

ARD

W20

W24

W26

W22

12

11

10

09

07

08

06

05

04

Gnd (

W8 thru 

W14)

Dr

ain A

lar

m #1 I

nput

Lo

w P

ressur

e S

w

. I

nput

Hea

ter #1 ON I

nput

High P

ressur

e S

w

. I

nput

Alar

m A C

om.

Compr

essor #1 ON I

nput

Alar

m A N/C

Alar

m A N/O

W15

W13

W14

W11

W10

W9

W8

W21

W19

Alar

m B N/C

Alar

m B C

om.

Dr

ain T

est 

O

utput

Alar

m B N/O

Dr

ain T

est 

O

utput

Compr

essor #1 O

utput

Compr

essor #1 O

utput

W27

W18

W17

W16

N/A

N/A

W25

W23

FR

OM SHEE

T 01

01

03

02

00

Chassis Gnd

.

TB2

X

24V

AC IN

24V

AC IN

W3

W2

W1

X

TB2

3

X

REMOVE JUMPER IF OPTIONAL DR

AIN INST

ALLED

TB2

TB2

TB2

TB2

TB2

19

20

21

18

17

19

20

21

18

17

14

16

15

13

12

14

16

15

13

12

16

TB2

TB2

TB2

20

18

19

17

TB2

TB2

14

12

15

15

13

TB2

TB2

TB2

10

11

9

8

10

11

9

8

7

6

4

5

7

4

TB2

TB2

10

8

11

9

TB2

4

7

X

CONT 1

19

16

20

19

18

17

CONT 1

19

4

8

7

BLU

TB2

CONNEC

TOR

PE

2

1

PE

2

1

PE

BRN

RED

BRN

F1

LO

AD

LINE

WHITE

PE

BLU

TB2 19

18

19

HPS/LPS SENSOR HARNESS

17

19

HPS

LPS

HPS

4

6

3

1

1

3

6

4

TB2 19

TB2

PE

DR

AIN 2 HARNESS

X

N

20

19

7

8

5

3

2

8

7

19

20

N

X

5

3

2

DR

AIN 1 HARNESS

4

24V

AC

ALM

TEST

TEST

ALM

24V

AC

COMPRESSOR CONT

AC

TOR

N

FR

OM SHEE

T 01

TB2

N

BLACK

WHITE

DB9 M

ALE C

ONNEC

TOR

(M

oun

ted in Enclosur

e)

3

8

9

5

RED

4

6

7

2

1

-4NO

-3NO

-1NC

-2NC

CONT 1

A1

A2

Summary of Contents for TF 171E

Page 1: ...NG 2 1 0 INSTALLATION 3 2 0 OPERATION 5 3 0 MAINTENANCE 8 SIZING 8 ENGINEERING DATA 9 WIRING DIAGRAM Model TF 171E 10 11 Model TF 210E 12 13 575 460 3 60 Transformer Pack 14 DIMENSIONS WEIGHTS 15 TROU...

Page 2: ...our plant It was received in good condition by the carrier and was so acknowledged Check for Visible Loss or Damage If this shipment shows evidence of loss or damage at time of delivery to you insist...

Page 3: ...d 45 to 130 F 7 to 54 C E Installations in altitudes above 4500 feet 1370 meters Dryer is adjusted to operate in altitudes up to 4500 feet 1370 meters If dryer is installed in an altitude above this a...

Page 4: ...manual draining convenient dryer depressurization and EDD service a three way valve assembly has been installed at the bottom of the moisture separator and cold coalescing filter where applicable Rev...

Page 5: ...the pilot air supply line and opening the pilot air exhaust line After the pilot air above the diaphragm 4 is vented pressure in the reservoir opens the discharge port and forces the condensate throug...

Page 6: ...m on or off use On Off button Push Schedule On Off and Enter button to return to schedule NOTE After power interruption dryer will reenergize in Manual override refrigeration system off To restart Sch...

Page 7: ...contact on the compressor contactor is open when the dryer is off TEMP SENSOR Occurs if the temperature sensor circuit is open or shorted If open the left most LED in the temperature display will be i...

Page 8: ...tiply the rated capacity from Table 1 by the multipliers shown in Table 2 Example How many scfm can an air cooled model TF 171E handle when compressed air to be dried is at 200 psig and 100 F ambient...

Page 9: ...psig 9 3 barg Required Available Water Pressure Differential 40 psig 2 8 barg minimum Flow Required with 85 F Cooling Water gallons per minute 60 Hz 4 9 6 8 50 Hz 4 1 5 6 Electrical Data Nominal Volta...

Page 10: ...only FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE TB1 L1 L2 L3 L1 L1 L1 L2 L3 CONT 1 PE TB2 T1 T2 T...

Page 11: ...5 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET 01 01 03 02 0...

Page 12: ...HEATER 1 FAN 2 HARNESS FPS 2 FAN 2 REF SHEET 02 LINE 11 REF SHEET 02 LINE 10 REF SHEET 01 LINE 20 03 10 11 12 09 08 07 06 05 04 L3 L3 L3 L2 L2 02 01 00 PE L1 L1 L1 L2 L3 TB1 L1 L3 L2 CONT 1 DISCONNECT...

Page 13: ...5 W13 W14 W11 W10 W9 W8 W21 W19 Alarm B N C Alarm B Com Drain Test Output Alarm B N O Drain Test Output Compressor 1 Output Compressor 1 Output W27 W18 W17 W16 N A N A W25 W23 FROM SHEET 01 01 03 02 0...

Page 14: ...14 WIRING DIAGRAM 575 460 3 60 Transformer Pack...

Page 15: ...25mm ELECTRICAL ENTRY 750 19mm RS 232 ACCESS 0 25 NPT DRAIN CONNECTION MODEL TF171E 0 25 NPT DRAIN CONNECTION MODEL TF210E Dimensions inches mm Model TF 171E TF 210E A 58 06 1475 58 06 1475 B 32 15 81...

Page 16: ...enser cooling Air cooled Ambient temperature too high clogged condenser fins obstructed flow across condenser faulty fan motor or fan control switch Water cooled Cooling temperature too high flow too...

Page 17: ...30763 Hot Gas By Pass Valve Air Cooled 5002351 5002351 5002351 5002351 Filter Dryer Liquid Line 5002925 5002925 5002925 5002925 Temperature Sensor 3210926 3210926 3210926 3210926 Contactor 5002926 500...

Page 18: ...18 NOTES...

Page 19: ...19...

Page 20: ...price of the product or part THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORAL OR STATUTORY AND IS EXPRESSLY IN LIEU OF THE IMPLIED WARRANTY OF MERCHANTABIL...

Reviews: