12 Decommissioning, Storage and Transport
12.1 De-commissioning
De-commissioning is necessary, for example, under the following circumstances:
■ The machine is (temporarily) not needed.
■ The machine is to be moved to another location.
■ The machine is to be scrapped.
➤ The following tasks are to be performed by authorised personnel only.
12.1.1 Temporary de-commissioning
Precondition The machine can be started at regular intervals.
➤ Run the machine once a week for at least 30 minutes under LOAD to ensure sufficient protec‐
tion against corrosion.
12.1.2 Long-term de-commissioning
Precondition Immediately prior to de-commissioning, run the machine in LOAD operation for at least 30 minutes.
12.1.2.1 Draining condensate
If the machine is equipped with a condensate drain, drain condensate from the condensate drain.
Precondition The machine is switched off.
1. Drain condensate from the condensate drain and dispose of according to applicable environ‐
mental protection regulations.
2. Remove the user-supplied condensate lines.
The condensate drains are not supplied with power when the machine is switched off?
➤ Detach and drain the condensate drains.
12.1.2.2 Isolating the machine from supply lines
Precondition The power supply isolating device is switched off,
it has been locked off against unintentional reactivation and
the absence of voltage has been verified.
The machine is fully vented (depressurised).
The user's shut-off valve to the compressed air network is closed or the compressed air network
has been fully vented.
1. Allow the machine to completely cool down.
2. Detach the power supply and connecting line to the compressed air network at the user side.
3. Option W1:
Remove the user-supplied connecting lines.
4. Properly close all open connecting ports.
12 Decommissioning, Storage and Transport
12.1 De-commissioning
84
Operating Manual Rotary screw compressor
SK
901848 21 E
Summary of Contents for SK Series
Page 2: ...Original instructions KKW SSK 2 21 en SBA SCHRAUBEN SC2IO KKW SSC 2 08 20180629 105600...
Page 6: ...Contents iv Operating Manual Rotary screw compressor SK 901848 21 E...
Page 8: ...List of Illustrations vi Operating Manual Rotary screw compressor SK 901848 21 E...
Page 10: ...List of Tables viii Operating Manual Rotary screw compressor SK 901848 21 E...