Fig. 34 Checking condensate drainage
1
LED
2
«TEST» key
➤ Visual check: Does condensate flow as soon as the LED illuminates?
Condensate does not flow?
The condensate drain hose or the drain itself is blocked.
➤ Switch off the machine and clean the drain pipe.
➤ Condensate drain manual check: Press and hold the «TEST» button for at least 2 seconds.
➤ Carry out maintenance on the condensate drain if condensate still does not flow.
➤ Collect condensate in a suitable container and dispose of it in accordance with applicable
environmental regulations.
10.16.2 Exchanging the service module
Precondition The power supply isolator is switched off (all poles),
the device is secured to prevent switching back on,
the absence of voltage has been verified.
Fig. 35 Exchanging the service module
1
Service module
2
Control module
3
Sensor
4
Sensor opening
5
Snap fastener
6
Condensate drain hose fitting
7
Contact spring
8
Inlet
10 Maintenance
10.16 ECO-Drain automatic condensate drain
62
Service Manual 2-stage piston compressor
EPC
No.: 9_9431_02 E