Initial Start
7 --- 26
7.6
Motor Overload Protection Switch Adjustment
Before any adjustments are carried out to the compressor package,
lock the main disconnect in the ”off” position in accordance with appli-
cable lock out/tag out procedures (example: OSHA CFR 29 § 1910.147)
to ensure the compressor does not restart.
See chapter 2.3 for the main disconnect switch.
The standard setting is made at the factory.
Fan Motor: direct on-- line start
In direct on ---line start the starting current is fed via the motor overload protection switch.
For the nominal motor current see motor nameplate.
Adjustment:
This can be set to a maximum of 10% higher than the rated motor current to prevent trig-
gering of the motor overload protection switch under conditions of voltage fluctuation.
3
2
1
1 Fan motor overload protection relay
2 Fan motor overload adjustment
3 Reset button
7.7
Setting the Air System Pressure
The air system pressure is preset at the factory. It can be changed in SIGMA CONTROL to
match customer’s operational requirements if the password is known. For further details,
consult the SIGMA CONTROL service manual.
Summary of Contents for CSD 75
Page 2: ......
Page 11: ...Technical Specification 1 6...
Page 19: ...Construction and Operation 5 14...
Page 20: ...Construction and Operation 5 15...
Page 58: ...Appendix 11 53 11 Appendix 11 1 Wiring Diagram...
Page 59: ......
Page 60: ......
Page 61: ......
Page 62: ......
Page 63: ......
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......
Page 68: ......
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......
Page 73: ......
Page 74: ......
Page 75: ......
Page 76: ......