Inhalation
Cooling oil mist may make breathing difficult.
➤ Clear air passages of oil mist.
➤ Seek medical help if difficulty with respiration continues.
Ingestion
➤ Wash out the mouth immediately.
➤ Do not induce vomiting.
➤ Seek medical aid.
3.9.3 Injury from Handling Refrigerant
Eye contact:
Severe eye irritation, watering, reddening and swelling of the eyelids.
Risk of caustic burns and frostbite.
➤ Open eyelids wide to allow product to evaporate.
➤ Hold the eyelid wide and rinse the eye with running water.
➤ Consult an ophthalmologist if you experience lasting pains.
Skin contact:
Initially a sensation of chill, skin may redden subsequently.
Risk of frostbite.
➤ Allow the product to evaporate.
➤ Rinse with lukewarm water.
➤ Consult a physician if experiencing lasting pain or reddened skin.
Inhalation:
At high concentrations, risk of cardiac irregularity (arrhythmia).
At very high concentration, risk of asphyxia caused by oxygen deficiency.
➤ Remove victim to the fresh air.
➤ If necessary Respiration with respirator or administration of oxygen.
➤ Consult a physician if experiencing breathing or nerve complaints.
3.10 Warranty
This operator manual contains no independent warranty commitment. Our general terms and con‐
ditions of business apply with regard to warranty.
A condition of our warranty is that the machine is used for the purpose for which it is intended un‐
der the conditions specified.
Due to the multitude applications for which the machine is suitable the obligation lies with the user
to determine its suitability for his specific application.
In addition, we accept no warranty obligation for:
■ the use of unsuitable parts or operating materials,
■ unauthorized modifications,
3
Safety and Responsibility
3.10 Warranty
24
Operator Manual Screw Compressor
AIRTOWER 3C–7.5C Tri-Voltage
9_6917 34 USE