Fig. 8 Transport with a crane
1
Eye bolt
➤ Screw the supplied eye bolts diagonally into the prepared holes in the block base.
➤ Lift and transport only by means of the eye bolts.
12.4 Storage
Moisture can lead to corrosion, particularly on the surfaces of the blower block. Storage tempera‐
ture must not fall below −30 °C.
Advice can be obtained from KAESER on storage and recommissioning.
NOTICE
Damage to the block by moisture and frost.
➤ Prevent ingress of moisture and formation of condensation.
CAUTION
Rotating piston!
Danger of squashing or severing of limbs.
➤ Do not reach into the interior of the block.
➤ Store the block in a dry room.
➤ Protect the flange connections, drive shaft and delivery space of the block by spraying with ap‐
propriate an conservation oil, e.g., ANTICORIT OHK.
➤ Seal openings at the block to prevent the introduction of foreign particles and dirt.
■ Screw closing plugs into bores.
■ Close flange connections with plastic caps.
➤ Change the lubricating oil annually.
After lengthy storage
➤ Remove the preservative from the flow chamber with cleaning solvent.
➤ Change the lubricating oil.
12 Decommissioning, Storage and Transport
12.4 Storage
Number: 9_9533 23 E
Assembly and operating manual Blower block
OMEGA 4 B
39