background image

‘FlexControl 14’                                                         page 8/11                                                    Firmware version 1.x 

Suggested configuration of digital input pins, depending on the type of activators, attached to them 

 

↓ - On falling edge

 

↑ - On rising edge

 

    

 

 
 
 
 
 
 
 
 
 
 
 
 

  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

In the ‘Options’ tab, You may adjust the following parameters: 
 
-

 

Startup  delay,  [ms]

:  It  may  be  useful  if  Your  tube  amplifier  needs 

warmup. The device will not switch the outputs during that period.  In 
milliseconds. 

-

 

Always  start  with  last  output  states

:  Check  this  if  You  want  the 

FlexControl  to  memorize  the  states  of  the  outputs,  so  at  the  next 
powerup to start where You left. 

-

 

Reset range calibration of analog inputs

: Relevant only for input pins, 

which  are  configured  with  analog  function.  Check  this  box  when 
changing the potentiometers, connected to the analog inputs. 

-

 

Use  mutex  memory

:  enables  memorization  of  non-mutex  digital  outputs  (if  there  are  any)  against 

currently active mutex output. When the same mutex output gets active again, the rest of the outputs 
will be restored automatically. 

-

 

MIDI Rx channel:

 Defines the MIDI channel to ‘listen’ for incoming messages. 

 

Activator 

Class 

Type 

Desired output 

interdependence 

Output reactions 

↓ 

Set 

Mutex 

↑ 

None 

↓ 

Toggle 

Non-

retentive/ 

momentary 

Pushbutton 

No 

↑ 

None 

↓ 

Set 

Switch 

(visible state) 

No 

↑ 

Clear 

↓ 

Toggle 

No 

↑ 

Toggle 

↓ 

Set 

Switch 

(invisible state) 

Mutex 

↑ 

Set 

↓ 

Set 

Retentive 

Rotary switch 

Mutex 

↑ 

None 

Summary of Contents for FlexControl 14

Page 1: ...FlexControl 14 page 1 11 Firmware version 1 x FlexControl 14 User s manual Firmware v1 x www kae systems com...

Page 2: ...p for buttons or switches up to 11 analog inputs for potentiometers All digital inputs and outputs go out on standard 2 54mm male connectors 1 MIDI In DIN5 connector 1 MIDI Out Thru DIN5 connector Sem...

Page 3: ...11 of the inputs can be configured as analog thus allowing potentiometers to be attached to them The result of analog to digital conversion is a 7 bit value which is optionally transformed see charts...

Page 4: ...27 Input values are on horizontal axes The chart represents actual values Digital PWM outputs All of the 14 output pins can be configured as digital and are suitable for active or inductive loads rela...

Page 5: ...I channel Configurable Rx MIDI controllers CC for digital outputs Configurable Tx MIDI controllers CC for analog inputs Configurable MIDI presets retrievable on reception of Program Change MIDI messag...

Page 6: ...Remote outputs copy the state of the Host s outputs Working with the FlexControl Configurator All parameters of the firmware profiles can be configured with few mouse clicks with the help of the FlexC...

Page 7: ...ues You may refer to the available transformation curves in the chapter Transformation charts Output directly to PWM If set to true the PWM duty cycle of the corresponding output pin will change propo...

Page 8: ...et range calibration of analog inputs Relevant only for input pins which are configured with analog function Check this box when changing the potentiometers connected to the analog inputs Use mutex me...

Page 9: ...oard off and on make sure the preconditions are correct and try again MIDI preset programming sequence without computer Applicable only to firmware profile Host Assuming already configured with the co...

Page 10: ...t load per output 500 mA Power consumption 26 mA 12V no loads connected all outputs off LED off MIDI implementation chart Message type Can receive Can send Note off 8x Yes Note on 9x Yes Polyphonic af...

Page 11: ...FlexControl 14 page 11 11 Firmware version 1 x Straight through Ethernet cable pinout Mechanical parameters All dimensions in millimeters...