Diagram 17
NOTE
For Networker connection to KU3, KE3 and KE4 models a Kaden 539 interface is required, Kaden
Part No. 1621292
8.2 PROGRAMMABLE WALL CONTROL INSTALLATION
8.2.1 Wiring the Programmable Wall Control to a KU4 Heater
IMPORTANT
The Programmable Wall Control backing plate has 8 terminal points for the connection of control
wires. When connecting, use
ONLY
the two top terminals marked RH and W. Ensure that the R
(RH) and W polarity is correct at both ends of the wire cable.
A Kaden Programmable Wall Control can be wired directly to a Kaden KU4 heater as follows:
•
Run a twin wire cable (i.e. figure 8 cable - 0.75mm2) from the heater to the Programmable Wall Control.
•
Remove the backing plate from the Programmable Wall Control by unclipping it at the sides.
•
Draw the wires from the wall cavity and feed them through the opening in the backing plate.
•
Connect the cable to the terminal connections on the backing plate before mounting it to the wall refer to
Diagram 18.
•
Mount the backing plate onto the wall and then reassemble the controller.
•
Feed the cable through the grommet, located at a cabinet end.
•
Connect the other end of the cable to the terminals marked R and W in the heater’s electronic control module,
refer to Diagram 18.
W
RH
B
RC
G
O
Y
+
-
+
-
GAS
ELEC
W904
W905
W903
RH
W
R
W
Prommable Wall Control
Back Plate
KU4
Control Board
Grommet for
control cable
access
Diagram 18