25
7.1 OUTLET REGISTER CHART
System Model
Airflow
Rate (L/s)
A
B
C
Recommended
Maximum Ceiling
Min' Floor / Ceiling
Min' Floor / Ceiling
(Adaptive Zoning Only)
Universal Heaters
KU5
KU521
785
12
5
1.5
KU530
1000
17
7
2
KU4
KU415
620
10
6
2
KU420
620
10
6
2
KU425
630
10
6
2
KU430
895
16
7
2
KU3
KU315
475
10
5
N/A
KU320
540
10
5
N/A
KU325
650
11
6
N/A
KU330
895
13
8
N/A
External Heaters
KE4
KE415 (300mm)**
498
N/A
4
N/A
KE420 (300mm)**
581
N/A
5
N/A
KE420XA (350mm)**
622
N/A
5
N/A
KE428 (350mm)**
896
N/A
8
N/A
KE428XA (400mm)**
1012
N/A
8
N/A
KE3
KE315 (300mm)**
498
N/A
4
N/A
KE320 (300mm)**
581
N/A
5
N/A
KE320XA (350mm)**
622
N/A
5
N/A
KE328 (350mm)**
896
N/A
8
N/A
KE328XA (400mm)**
1012
N/A
8
N/A
** Model and base box duct size.
Table 6
NOTE
Airflow figures are based on a total static pressure of 125 Pa for 30 & 35 models and 50 Pa for
other models.
Kaden Network 516 modules can only be used on KU4 and KU5 model heaters for adaptive zoning.
Summary of Contents for KE3
Page 38: ...38 Kaden Installer s Manual Ducted Gas Heaters NOTES ...
Page 39: ...39 NOTES ...
Page 40: ...B063650 Issue A ...