Unobstructed air circulation.
Close to the ground, accessible from the front and sides without requiring additional resources.
Protected on all sides against direct weather exposure and sunlight (thermal heating) in outdoor areas. Implementa-
tion where necessary via constructional measures, e.g. wind breaks.
Installation surface
Must have adequate load-bearing capacity
Must be accessible for installation and maintenance
Must be made out of heat-resistant material (up to 90 °C )
Must be flame resistant
Minimum clearance during installation: [See figure 7] [
45 mm
140 mm
766,5 mm
735 mm
Fig. 3:
Drill stencil for device
Fig. 4:
Allowed installation position
6.2
Unpacking the device
↻
The device is transported to the installation location.
1 Remove the plastic band from the pallet and packaging.
2 Pull the hood upwards to remove it and place the cardboard packaging to one side together with the accessories.
3 Remove protective corners.
4 Remove the cover from the device.
»
The device is prepared for assembly and installation.
1
2
3
Fig. 5:
Unpacking the device
4
5
Fig. 6:
Transport device for erection purposes
Key
1
Cardboard box cover
4
Cover
Powador 39.0TL3 , Powador 39.0 TL3 M1 , Powador 40.0 TL3 , Powador 48.0 TL3 Park , Powador 60.0 TL3 ,
Powador 72.0 TL3 Park
Page 14
EN