NOTE: The minimum clearances between two devices, or the device and the ceiling/floor have already been taken
into account in the diagram.
3 Fix the mount to the wall using suitable mounting fixtures from the mounting kit.
NOTE: Make sure that the mount is oriented correctly.
»
Proceed with the installation of the device.
6.4
Installing and securing the device
CAUTION
Risk of injury from improper lifting and transport.
Lifting the device improperly can cause the device to topple and fall over.
›
Only ever raise the device vertically using the openings provided.
›
Use a climbing aid for the chosen installation height.
›
Wear safety gloves and safety shoes when lifting and lowering the device.
NOTE
Power reduction due to heat accumulation!
If the recommended minimum clearances are not observed, the device may go into power regulation
mode due to insufficient ventilation and the resulting heat build-up.
›
Observe the minimum clearances and provide for sufficient heat dissipation.
›
Any objects on the housing of the device must be removed prior to operation.
›
Make sure that foreign objects cannot hinder heat dissipation following installation of the device.
1
2
3
Fig. 18:
Lifting the device by the opening
4
3
Fig. 19:
Fitting the device onto the mount
Legend
1
Opening
3
Mounting bracket
2
Center of gravity
4
Mount
Lifting and mounting the device
↻
The mount has been installed.
1 Lift the device using the lateral openings. Have regard to the position of the device's center of gravity!
NOTE: Do not lift the device by the lid or cover!
2 Fit the device onto the upper mount by means of the mounting bracket. Fit the device onto the lower mounting
bracket in full so that the device sits flush with its rear side on the mount. ( [See figure 17] [
Page 18]).
KACO blueplanet 87.0 TL3 KACO blueplanet 92.0 TL3 KACO blueplanet 110 TL3 KACO blueplanet 125 TL3
KACO blueplanet 137 TL3 KACO blueplanet 150 TL3
Page 19
EN-US