background image

Instruction manual  Kabola KB-Series version 6,  2018

26

Pos

Description

Article number

 

1

Boiler housing

2

Dashboard KB-series 230V

51-001

3

Stainless steel efficiency tube only KB20

44-005

4

Insulation boiler  KB40 300 x 300 x 20 mm

46-005

4

Insulation boiler  KB45/KB50 327 x 299 x 20 mm

47-005

4

Insulation boiler  KB75 420 x 360 x 20 mm

49-005

5

Door gasket

9-I083

6

Insulation door KB40 282 x 282 x 15 mm

46-004

6

Insulation door KB45-KB50 310 x 282 x 15 mm

47-004

6

Insulation door KB75 404 x 342 x 15 mm

49-004

7

Door

-

8

Bolt M10

-

9

On request

-

10

Burner plate

-

11

Burner Block Module

52-001

12

Ring adapter for burner module

52-002

13

Adapter tube 80 x 1.5 x 109 mm

52-003

14

Burner tube KB-serie

52-004

15

Seal for KB-burner

52-005

16

Door bolt with shim

52-006

17

Feed burner control LOA24

52-007

18

Burner connector 7 pole KB-series

52-008

19

Burner controlt LOA24

52-009

20

Motor 70 watt

52-010

21

Bearing plate for oil pump motor

52-011

22

Oilpump coupling KB-series

52-012

23

Scheer oil pump KB-series

52-013

24

Oilhose KB-series

52-014

25

Blower fan RG148 KB-series

52-015

26

Seal adapter tule

52-016

27

Seal for nozzle stem retaining plate

52-017

28

Nozzle KB40

52-019

28 

Nozzle KB50

52-046

28

Nozzle KB45

52-020

28

Nozzle KB75

52-021

29

Dosage ring KB-series

52-022

30

Mixing cartridge complete KB40

52-024

30

Mixing cartridge complete KB45

52-025

30

Mixing cartridge complete KB50

52-025

30

Mixing cartridge complete KB75

52-026

31

Nozzle holder complete KB40

52-027

31

Nozzle holder complete KB45-KB50

52-028

31

Nozzle holder complete KB75

52-029

32

Electrode KB40-KB45

52-030

32

Electrode KB50-KB75

52-031

33

Flame detector KLC2002

52-032

34

Mounting plates  for number. 35, 36 en 37

-

35

Ignition transformator

52-033

Summary of Contents for Ecoline series

Page 1: ...User manual KB ECOLINE series English Ecoline serie CH Calorifier Combi...

Page 2: ...ions that can be identified in the following way Hint This gives the user suggestions and advises to facilitate the execution of certain tasks Attention Additional information is supplied to the user...

Page 3: ...stem and domestic hot water 8 4 1 3 Flue gas outlet 9 4 1 4 Electrical connection 12 4 1 5 Filling the central heating system 14 4 1 6 Mounting the oil filter and oil burner 15 4 2 Starting your syste...

Page 4: ...and for a central heating system The boilers can also be used for the generation of domestic hot water generated by a compact brazed heat exchanger The dimensions of the rooms to be heated have to be...

Page 5: ...ions In this chapter we emphasis the safety related points for operating the boiler MEASURES FOR A SAFE INSTALLATION Don t store any flammable and or gaseous products in the room where the boiler is i...

Page 6: ...fuel system While transporting the boiler take following precautions Don t damage the boiler use a blanket to cover the boiler Transport the boiler standing up 3 2 Storage Take the following precauti...

Page 7: ...Fitting the boiler Install the boiler in a dry place Install the boiler on a firm horizontal base Make sure there is sufficient supply of fresh air in the room where the boiler is installed see hint...

Page 8: ...r Attention Install a bleeding point near the boiler especially when the piping does not go up Installation KB CH Connect the piping to the boiler as follows see figure 2 2 2 1 Install the feed of the...

Page 9: ...e return of the boiler and Calorifier on nr 2 3 Install the feed of the boiler on 3 A 4 Install the fill and pressure gauge on nr 4 5 The numbers A and B you will find on the housing of the three way...

Page 10: ...sulate the flue with heat resistant material on those parts where contact with human body parts is possible For a correct flue gas outlet the following points need to be observed Use the proper diamet...

Page 11: ...nter large angles of heel through waves and under sail For this kind of flue gas outlet the following points are important Install a proper storm cowl on top of the chimney this must stop rain from en...

Page 12: ...e boiler before you start the installation The quality of 230 VAC power supply to the boiler should be as good as the power supply from a land line To connect the room thermostat for KB Standard Remov...

Page 13: ...B4 in connection A figure 11 at the backside of the dashboard as shown on the sticker inside the connector Connect the wires inside the room thermostat Fig 6 1 to Q14 T1 and Q11 T2 Connect the Frost...

Page 14: ...m can be filled with cooling fluid suited for CH systems pH value 8 5 Bleeding the circulation pump Adjust the temperature of the room thermostat higher than the ambient temperature for example 5 degr...

Page 15: ...version 2 Switch the boiler on at the on off switch on the control panel The lamp in the switch indicate that the system is on 3 Set the room thermostat see manual of the room thermostat 4 Open the va...

Page 16: ...oom thermostat If problems arise with the operation of the boiler you will find a list of possible problems and solutions in Appendix C 5 1 Explanation of the dashboard KB series Boiler Display On off...

Page 17: ...stand by Circulationpump not active 1 Room thermostat is demanding Circulation pump active 2 Hot water is being tapped or external boiler requires heat Circulation pump active 3 Pumptimer active Circu...

Page 18: ...you just want to use tap water and no heating you ll have to proceed the following steps 1 If the tap is visible at the display of the room thermostat than the tap water is switched on If not it s sw...

Page 19: ...anual preferably an expert installer or a service engineer from Kabola Heating Systems Every year 1 Clean the boiler 1 1 Remove the burner with the door from the boiler 1 2 Remove the insulation 1 3 C...

Page 20: ...Instruction manual Kabola KB Series version 6 2018 20 Appendix A Technical specifications...

Page 21: ...Instruction manual Kabola KB Series version 6 2018 21 Appendix B Electrical diagram 230 V...

Page 22: ...Instruction manual Kabola KB Series version 6 2018 22 Appendix B Electrical diagram 230 V...

Page 23: ...of flame at the end of safety time Faulty or soiled fuel valves Faulty or soiled flame detector Poor adjustment of burner no fuel Faulty ignition equipment 3x blinks alarm on terminal 10 Free 4 blink...

Page 24: ...Instruction manual Kabola KB Series version 6 2018 24 Appendix D Boiler parts model 2012 2016...

Page 25: ...Instruction manual Kabola KB Series version 6 2018 25 Appendix D Boiler parts model 10 2016 2017 Spareparts list model 2012 2016...

Page 26: ...7 Feed burner control LOA24 52 007 18 Burner connector 7 pole KB series 52 008 19 Burner controlt LOA24 52 009 20 Motor 70 watt 52 010 21 Bearing plate for oil pump motor 52 011 22 Oilpump coupling KB...

Page 27: ...24 x063 44 Knee type221 1 18 S482 45 Conversion ring 1 bui x bin 18 S297 46 Pipe nipple x 120 mm 18 S483 47 48 Fill and pressure gauge 9 I015 50 Tap casing 51 Back of tap casing 52 Heat exchanger 24 x...

Page 28: ...Instruction manual Kabola KB Series version 6 2018 28 Spareparts list model 2016 2017...

Page 29: ...er our own responsibility that the product Kabola KB20 KB40 KB45 KB50 KB75 combi 230V to which this declaration relates complies with the fol owing standards EN 303 1 EN 303 2 EN 304 EN 50081 1 EN 500...

Page 30: ...Instruction manual Kabola KB Series version 6 2018 30 Appendix F CE declaration...

Page 31: ...Instruction manual Kabola KB Series version 6 2018 31 Warranty Conditions...

Page 32: ...Instruction manual Kabola KB Series version 6 2018 32 Appendix G Guarantee conditions...

Reviews: