Pass a programming key card over the Q90 RFID reader. The green light will stay illuminated for 30 seconds. This will 

indicate the lock is ready to be programmed. After programming, present the emergency keycard. The mechanism will 

unlock.

Lock Communication 

 

Electronic Function Description

Green LED illuminates for 

 

 

Time and date not set, use the Q90 RFID LPI probe to reset. 

30 seconds

 

 

This will be done during programming or using the FDU to reset the time

Red LED flashes 12 times

 

 

Dead bolt is thrown or switch cam is not properly aligned

No light

 

 

Keycard not allowed OR keycard cancelled by new keycard

Red and green LEDs flash

 

 

Low battery (contact the ILCO service department). 

8 times use staff

 

 

Must alternately or emergency keycard to see this feedback

Yellow and red LEDs flash

  

 

Bad keycard read or corrupted data (may require new keycard) 

2 times simultaneously

 

No visual feedback

Testing Lock Functionality

Summary of Contents for Quantum Series

Page 1: ...INSTALLATION GUIDE ILCO Q90 RFID Quantum Series PK3656...

Page 2: ...stitute parts will result in poor performance of the lock Proximity Reader Assembly Mortise Scalp Plate Outside Lever Trim Screw Pack Strike Plate Inside Trim Assembly All information contained herein...

Page 3: ...0 mortise lock Drill fixture If you are using a Q90 drill fixture position and clamp the fixture on the door The fixture has two positioning posts that rest inside the mortise establishing the proper...

Page 4: ...rtise front plate to the door using the two mortise screws 12 x 1 1 4 screws for wood doors 12 24 x 3 8 screws for metal doors Be sure that the screws are fully tightened Important DO NOT leave the sc...

Page 5: ...ECTOR 3 Position the inside trim on the inside of the door 4 Secure inside trim to the proximity card reader assembly to the inside trim using three 8 32 x 1 1 4 screws Important Do not fully tighten...

Page 6: ...hould be at the top bottom 12 00 and 6 00 position when the mortise dead bolt is retracted see Fig 6 The retaining ring should rest on the switch cam when fully inserted the proper positioning of the...

Page 7: ...as indicated in the following section and in the programming manual before closing the door When the installation keycard is used the green and red LEDs will blink together then the green LED will bl...

Page 8: ...et use the Q90 RFID LPI probe to reset 30 seconds This will be done during programming or using the FDU to reset the time Red LED flashes 12 times Dead bolt is thrown or switch cam is not properly ali...

Page 9: ...es once when a valid guest card is presented while privacy is enabled Access is denied The red LED flashes 8 times when a staff card is presented while privacy is enabled Access is granted Door functi...

Page 10: ...1 514 735 5410 General Information www kabalodging com Online Consumable Orders www ilcostore com To access all of our easy steps please visit our Support Website www ilcosupport com Kaba Ilco Inc res...

Reviews: