Online operation with firmware option Subterminal
56
k4evo707en-2012-07
6.4.2
Overview of DIP switches
Firmware option Subterminal
Switch 1
ON
Terminating resistor 4.7 k
Ω
OFF
Open
Switch 2
ON
Terminating resistor 120
Ω
(B-web 93 00 operation)
OFF
Open
Switch 3
ON
-
OFF
-
Switch 4
ON
The interface parameters and the GID/DID that have
been set via the LOWPAR command in system mode
are active (only for special applications)
OFF
The DID peripheral address set via the rotary switch is
active, the GID group address is fixed at 00. The
Compact Reader automatically detects the baud rate of
the sub-party line, 9,600 or 19,200 (default).
Switch 5
ON
The Compact Reader is started after switch-on in system
mode (service/setup)
OFF
The device software is started after switch-on
(regular start)
Switch 6
ON
Cold start/programming mode
See Chapter 6.7/Page 58
OFF
Regular start
6.4.3
Addressing the Compact Reader
Firmware option Subterminal
DID logical peripheral address
Note:
The GID logical group address is fixed at 00
Position Peripheral
address
Position
Peripheral
address
0 DID
16 8
DID 08
1 DID
01 9
DID 09
2 DID
02
A
DID 10
3 DID
03
B
DID 11
4 DID
04
C
DID 12
5 DID
05
D
DID 13
6 DID
06
E
DID 14
7 DID
07
F
DID 15