![Kaba MIFARE Technical Manual Download Page 17](http://html1.mh-extra.com/html/kaba/mifare/mifare_technical-manual_3141972017.webp)
Device description
k4evo707en-2012-07
17
2.5.2
Power supply (7)
Terminal
number
Meaning
1
- DC/AC
0 V DC/AC
2
+ DC/AC
10 … 34 V DC or 12 … 27 V AC, 50/60 Hz
Power consumption: typically 1.2 W; max. 2.2 W
For information on the maximum cable length, see Chapter 3.2.1 / Page 23
2.5.3 Output
OUT
(4)
One output
OUT
is available (e.g., an electric strike):
Terminal
number
Meaning
3
NC (normally closed)
4 COM
5 NO
(normally
open)
2.5.4
Connecting the tamper switch (6)
Where necessary, the
external
tamper monitoring function of the Compact Reader can be
connected. As soon as the PCB (in the housing) is lifted off the mounting plate plug, this
interruption to the connection (e.g., at the input of the parent control unit) can be evaluated as
sabotage. When closed, terminals 6 and 9 are connected to the PCB via a 680 ohm resistor.
Terminal number Meaning
9 Tamper
switch
(tamper)
6
GND (common ground)