Version 2014-02-28
Page 35 of 48
Operating instructions 82132/3XXX - Combi B 30
24.1
Changing master code (P)
After modification of the master code the previous master code is no longer valid. The function of the new master code must be
checked by opening the lock with the secure storage unit open (see chapter 10.1)!
Description
1. Press
and enter the current master code
and
(00 = ID, X = previously programmed 6-digit combination)
2x 3x 3x
2. Enter the new master code
and
(00 = ID, Y = new 6-digit combination)
2x 3x 3x
3. Confirm the new master code with
and
2x 2x 3x 3x
Table 35: Changing master code
The entire procedure has to be repeated in case of the following errors:
If Incorrect code signal is displayed according to 1. after the input of the current code, the code has been entered
incorrectly.
If the Incorrect code signal is displayed after the second attempt to enter the new code as shown in 3., then the two
codes entered in 2. resp. 3 do not match.
24.2
Programming functions for further codes (P3-P6)
This section describes the basic programming procedures for further codes (user or courier codes). This includes activation,
deletion, blocking and releasing of these codes. The basic code structure is given in chapter 5 authorizations. Furthermore, this
chapter describes the code status query used by the master code to request the status of individual codes directly from the lock.
For correct use of the lock the master code must be activated (see chapter 8.2).
24.2.1
Activating user codes or courier codes (P3)
Code can be used only after it has been activated. When activating a new operator, it is useful if the new code (starting fro m
item 3 of the following description) is entered directly by the respective operator on site. If the new code is not entered by the
operator directly but is specified by the master, it must be replaced by the real personal code in the course of code changing as
soon as possible (see chapter 10.7).
Description
1. Press
and enter the valid master code
and
(00 = ID, X = valid 6-digit combination for the master)
2x 3x 3x
2. Press
and
2x 3x 3x
3. Enter the new code
and
(ID = 01 to 30 for user resp. 95 for courier, X = freely selectable 6-digit combination [0..9])
2x 3x 3x
4. Confirm the new code with
and
2x 2x 3x 3x
Table 36: Activating code
After the activation the new saved code is valid and can be used. The new code has to be tested by opening the lock (see
chapter 10.1)!
If both entered codes do not match, the incorrect code signal is output after the second code input. If the Incorrect code
signal is displayed after the first code input, the code is already active or not available.