background image

Installation instructions

Installation

Kaba c-lever compact 

k2evo703en-2011-05

15

3. Fit the cover (12) over the internal 

rosette (10).

4. Push the handle (13) onto the 

spindle (8) until there is an 
audible click and fix with a fixing 
screw (14).

14

12

10

13

Summary of Contents for C-lever compact

Page 1: ...EN Kaba c lever compact Installation instructions Doc no k2evo703en 2011 05 ...

Page 2: ...lebühlstrasse 23 Postfach A 3130 Herzogenburg DE 63303 Dreieich CH 8620 Wetzikon Tel 43 0 2782 808 0 Tel 49 0 6103 99 070 Tel 41 0 848 85 86 87 Fax 43 0 2782 808 5505 Fax 49 0 6103 99 07 133 Fax 41 0 44 931 63 85 www kaba at www kaba de www kaba ch Kaba is a registered trademark of Kaba AG This documentation may not be reproduced in any way or otherwise used without the written consent of Kaba Gmb...

Page 3: ... for this product 7 2 2 1 ESD protective measures 7 2 2 2 Handling of lithium batteries 7 2 3 Disposal of packaging 8 2 4 Disposal of the actuator 8 2 5 Conformity 8 3 Product description 9 3 1 Scope of supply 9 3 2 Additional accessories 9 3 3 Preparatory measures 9 3 3 1 Door requirements 9 3 3 2 Lock requirements 9 3 4 Technical specifications 10 3 5 c lever compact assembly 11 3 6 Dimensions 1...

Page 4: ...roubleshooting 17 6 1 Maintenance 17 6 1 1 Replacing the battery 17 6 1 2 Setting the clock 18 6 1 3 Reading Traceback 18 6 1 4 Emergency opening for discharged batteries 19 6 2 INI reset 20 6 2 1 Initialising the electronic module 20 6 3 Cleaning 20 6 4 Troubleshooting 21 6 4 1 Possible faults 21 ...

Page 5: ...urpose The content of these instructions is limited to the installation and maintenance of the Kaba c lever compact Detailed information about programming can be found in the supplementary documentation 1 4 Supplementary documentation Technical information and help in the planning of installations can be found in the technical data sheets or the Kaba evolo catalogue Detailed information about prog...

Page 6: ...order to make it easier to read these instructions the Kaba c lever compact is shortened to actuator the 1460 programming device is shortened to programmer and the Kaba evolo Manager software is shortened to KEM CAUTION Indicates a potentially dangerous situation that can lead to minor injury Risk of explosion Indicates a potentially dangerous situation that can lead to minor injury ATTENTION Iden...

Page 7: ...re sensitive to electrostatic discharge ESD Contact by persons or objects can cause an electrostatic discharge that may damage or destroy the product To avoid the risk of electrostatic discharge note the handling guidelines and recommendations according to EN100015 1 Only transport and send removed modules in protective bags Risk of explosion Lithium batteries can explode or burst explosively Impr...

Page 8: ...of with waste for recycling 2 4 Disposal of the actuator Do not dispose of the actuator in household waste Dispose of electronic devices and used batteries in accordance with the Act on Disposal of Waste Electrical and Electronic Equipment Verordnung über Entsorgung von Elektro und Elektronik Altgeräten VREG WEEE at a local collection point for waste electronic equipment 2 5 Conformity This actuat...

Page 9: ... ordered at the same time from the catalogue 3 2 Additional accessories Adapter pins product number 1355 42A Programming cable product number 1355 42 Kaba 1460 Programmer Kaba media Kaba evolo Manager software 3 3 Preparatory measures 3 3 1 Door requirements The door thickness must be between 39 mm and 94 mm 3 3 2 Lock requirements The Kaba c lever compact can be used with most commercially availa...

Page 10: ...er supply Battery 2 x 1 5 V type AAA Lithium Service life 90 000 cycles or 3 years Operating environments Protection class IP54 Temperature 25 70 C 1 Humidity 0 95 rH non condensing Climate Not suitable for heavily corrosive atmospheres chlorine ammonia Rooms Not to be used in environments where there is a risk of explosion Standards Fire protection According to EN1634 1 EN179 According to test ce...

Page 11: ... Mechatronic unit 2 Housing 3 Metal ring 4 Plastic guide ring 5 External handle 6 Direction pin 7 Batteries type AAA Lithium 2 pieces 8 Spindle 9 Fastening screw 10 Internal rosette round optional 11 Fixing screw for internal rosette 2 pieces 12 Internal rosette cover optional 13 Inside handle optional 14 Fixing screw for handle optional 15 Centring sleeve 2 pieces 7 8 mm 2 pieces 7 9 mm 60 108 5 ...

Page 12: ...ve the lock before starting to drill Preparing the door 1 Remove the existing furniture or rosette fittings Mark the drill holes 2 Mark the drill holes if not in place according to the drawing on the outside and or inside of the door 3 Close the door lock If available the 2720 25 drill jig can also be used Drilling fixing holes 4 If there are no rosette drill holes drill the fixing holes with a Ø7...

Page 13: ...e read from the front on a right hand door and the L on a left hand door during use To make it easier to slide in turn the square spindle of the mechatronic unit 1 anti clockwise for right hand doors and clockwise for left hand doors as far as the limit stop when inserting the direction pin 6 Inserting batteries 2 Insert batteries 7 into the mechatronic unit 1 as shown Ensure correct battery polar...

Page 14: ...bly when fitting Inserting the spindle 6 Insert the spindle 8 into the square of the mechatronic unit 1 and secure with a fastening screw 9 If there are drill holes already in the door that are larger than Ø7 2 mm the centring ring 15 provided must be attached This prevents movement of the actuator in the door Inserting the actuator into the door 1 Position the actuator with the spindle 8 through ...

Page 15: ...ions Installation Kaba c lever compact k2evo703en 2011 05 15 3 Fit the cover 12 over the internal rosette 10 4 Push the handle 13 onto the spindle 8 until there is an audible click and fix with a fixing screw 14 14 12 10 13 ...

Page 16: ...d close programming window 1 x long 1 x green Authorised medium 1 x short 1 x green Unauthorised medium 4 x short 4 x red Master A B unauthorised 1 x long 1 x red Delete subgroup with authorised master 2 x short 1 x green Hold master medium in front of antenna for approx 10 seconds Soft INI reset with A B structure with authorised programming master A or with B structure with programming master B ...

Page 17: ...fficient capacity ATTENTION Opening the coupling unit absolves Kaba of any liability under the guarantee Risk of explosion Lithium batteries can explode or burst explosively Improper handling of lithium batteries can lead to fires and explosions Only replace lithium batteries with batteries of the same type No not open pierce or crush lithium batteries Do not burn lithium batteries or expose them ...

Page 18: ...ot been previously deactivated in the KEM software See Programmer user manual The events and data that are registered in the Traceback are listed in the kaba evolo system description Takingoffthehousingandchanging the batteries 1 Remove the metal ring 3 with guide ring 4 and housing 2 from the mechatronic unit 1 whilst pushing against the square of the coupling unit 2 Take out the batteries 7 and ...

Page 19: ...s were completely dead the door can only be opened from the outside using an authorised mechanical key and the key operated latch To be able to open the door mechanically in an emergency a lock with a key operated latch must be used or fitted Unlocking from the inside 1 With a panic lock the Kaba c lever compact can always be unlocked by operating the handle The relevant locking function is otherw...

Page 20: ...aning agents or methods Use a soft damp cloth to clean the facing Only disinfection agents that are specifically designed for delicate metal facings and plastics should be used Connecting INI contacts 1 Place authorised user medium or programming master in front of the antenna 2 Bridge connect the two initialisation points 1 with tweezers 3 Successful initialisation is confirmed by an acoustic dou...

Page 21: ...ntifies user 1 x long 1 x short 1 x long E module time data is missing Check the programming Repeated acoustic signal as system identifies user 2 8 x short 1 x green Battery low alarm Change batteries Repeated acoustic signal as system identifies user door does not open 1 x long 3 secs Battery low alarm Change batteries Door cannot be opened with programmed medium 1 x short 1 x green Coupling unit...

Page 22: ...Installation instructions Notes Kaba c lever compact k2evo703de 2011 05 22 ...

Page 23: ...23 k2evo703de 2011 05 Kaba c lever compact Notes Installation instructions ...

Page 24: ...Installation instructions Notes Kaba c lever compact k2evo703de 2011 05 24 ...