background image

8

E-730/630/750/79E/ RT Series Installation Guide - PK3677_T_04_16

Activate the panic bar. The latch bolt or rod 

retracts fully.

Turn the outside lever downward. The latch bolt 

or rod does not retract.
If the latch bolt or rod retracts, verify that 

the batteries are properly installed.
If the lever feels tight (hard to turn, or does 

not return easily to its horizontal rest position), 

check the spindle length vs. the door thickness 

(the spindle may be too long). Check that the 

slotted end of the spindle is inserted in the lock 

housing hub, not the exit device.

Test the lock’s response to keycards: a Test key-

card, a Grand Master keycard, and an Emergency 

keycard. 
Insert keycards as shown below, with the mag-

netic stripe facing toward the door and to the 

left. For 79E, present cards to reader.

A  Test the Lock Before Programming

Normal Entry: Use the Test keycard with the 

reader. The 

red

 and 

green

 LEDs each flash once 

and then the 

green

 LED flashes for four sec-

onds. 
Turn the outside lever downward while the 

green

 LED is flashing. The latch or rod retracts 

fully. Release the lever, then turn it again. The 

latch or rod must not retract after the LED 

stops flashing without first inserting the 

keycard .

B  Lock Programming

Program the lock with its Common Area number 

(exit devices are usually programmed as common 

areas, see Reference Manual).
Use the Grand Master keycard with the reader. 

The 

green

 LED flashes. Turn the outside lever 

downward while the 

green

 LED is flashing. The 

latch or rod retracts fully and the LED stops 

flashing after 4 seconds. Release the lever, 

then turn it again. The latch or rod must not 

retract again without first inserting the 

keycard .

C  Emergency Keycard Access

Use the Emergency keycard with the reader. 

The 

green

 LED flashes for 4  seconds. Then, turn 

the outside lever downward. The latch or rod 

retracts fully .

While standing outside the room, close the door 

and ensure that it is  properly latched. Open the 

door using the Grand Master keycard using the 

same procedure.

Caution! Perform the following procedures 

in order, with the door OPEN unless other-

wise indicated.

!

FDU

Program the lock using the FDU and the 

E-760/770/790 communication cable (see 

Reference Manual). If this is not a new installation 

but a replacement of a single lock or a group of 

locks in a property already equipped with the Kaba 

Locking system, transfer the security informa-

tion from a neighbouring lock to the new lock by 

using the Reset Addresses function (see Reference 

Manual resetting lock addresses). 

ATLAS

Program the lock using the M-Unit (Maintenance 

Unit). Refer to ATLAS User Guide.

I

n the case of a replacement lock resetting the 

addresses will ensure that all past lost and stolen 

keycards remain cancelled in the new lock and will 

set the addresses for the Section, Floor, Group, 

Zone and Area sub-master level so that staff key-

cards in use at the property will have the same 

pattern of access to the door as before. This step 

makes the lock replacement transparent so that 

the new lock accepts and rejects the same key-

cards as the old lock.

Multihousing

Program the lock using the M-unit or EAMU FDU.. 

Refer to RezShield User Guide or FDU user Guide.

1

  Panic Bar

2

  Outside Lever

3

  Electronics and Card Reader

 TEST THE OPERATION OF THE E-730/750/79E LOCK

 

(For 630 lock go to Section H) (For RT lock series, please refer to system 6000 manual)

 PROGRAM THE E-730/750/79E LOCK

 

(For 630 lock go to Section H) (For RT lock series, please refer to system 6000 manual)

Summary of Contents for 630 Series

Page 1: ...INSTALLATION GUIDE Exit Device Operators Generation E 730 630 750 79E RT Series E 730 Series 630 Series 750 Series 79E RT Series ...

Page 2: ... G Operating the Emergency Override 9 H Test the operation of the 630 Lock 10 J Installing the Mechanical Override 11 Parts and Tools List 11 1 Upon unpacking the Lock 12 2 Preparing the Outside Housing for the Installation of the Lever 12 3 Preparing the Lever Handle and Cylinder for Installation 13 4 Steps to attach the Lever Handle to the Lock Housing 13 5 Attaching the Lever Handle to the Lock...

Page 3: ...udes S Double enclosure T 2 X Pan Head Screws 8 32 X 1 2 Tools Required Safety glasses 5 16 7 9mm drill bit 1 2 13mm drill bit 1 25mm drill bit or hole saw Drill Awl or center punch Hammer Rubber mallet Small flat screwdriver Philips 2 screwdriver Spanner screwdriver No 6 1 8 Allen key Adjustable square Tape measure Pencil Tape Cleaning supplies drop cloth vacuum B A C D E F Q G H G J K E S COVER ...

Page 4: ...ep See Drilling Template 2 or 4 Holes Backset Vertical Line Inside of Door 4 Position the drilling template attached in this book let on the inside of the door aligning the door handle height mark and backset vertical line mark with the lines on the template Mark the door for the holes posi tion 5 Drill holes to diameters specified on the drilling tem plates Drill the holes in the door required fo...

Page 5: ...horizontal rest position appropriate to the handing of the door as shown Simply push the lever onto the tube until it clicks in place If more force is required to engage the handle use a rubber mallet Test the attachment of the handle by pulling smartly on it For mortise exit devices install the mortise according to the manufacturer s instructions The lever is field reversible If the handing is in...

Page 6: ... Adaptor Plate E using 2 screws or 4 screws H depending on the Exit Device For Detex only use 2 or 4 Flat washers Q 4 5 Make sure the lock and the Exit Device are well aligned and then tighten screws 4 6 Follow the manufacturer s instructions to complete the installation of the exit device and the appropriate strike Dorma 9300 9400 Series are Panic hardware only not fire rated Dorma F9300 F9400 Se...

Page 7: ... and re inserted if oriented incorrectly Choose a spindle that engages by 1 8 minimum in the exit device chassis and that it is not too long to bottom out against the exit device mecha nism to jam the lock assembly once it is tightened down 5 2 Pass wires W1 W2 through the gasket C and the hole H3 For the hollow doors the wires shall pass inside the door to come out from the hole H2 5 3 Place the ...

Page 8: ...rst inserting the keycard C Emergency Keycard Access Use the Emergency keycard with the reader The green LED flashes for 4 seconds Then turn the outside lever downward The latch or rod retracts fully While standing outside the room close the door and ensure that it is properly latched Open the door using the Grand Master keycard using the same procedure Caution Perform the following procedures in ...

Page 9: ...lect the Programming Menu then press Program 1 A lock 2 Another FDU 4 Wait 2 seconds Enter 1 to select the Lock option and press Enter Function 1 Program Addresses 2 Reset Addresses 5 Enter 7 to select the Override option then press Ready to perform an electrical override Strike a key or C to quit 6 Wait 2 seconds then press any key on the FDU to activate the electronic override The green LED on t...

Page 10: ...ts a day before today and finishes at least one day after installation testing date in order to avoid check in check out time periods B Code entry and access Enter the user code to validate complete lock operation Verify that the green LED flashes at each key pressed and a longer green LED flashes at the end of the code entry Turn the outside lever Make sure the latch bolt retracts fully Release t...

Page 11: ...t scewdriver less that 1 8 A Lock housing B Inside drive hub C Nylon washer D Spring washer Not for lever feel E Drive tube F Lever catch G Countersink H Lever handle I Cap J Cylinder K Cylinder plug L Override shaft K1 Set Screw Diagram of lock Facing view of drive tube E Back A H E B D F I J K K1 E L F G C Front J INSTALLATION OF THE MECHANICAL OVERRIDE ...

Page 12: ... Assemble the lever cylinder and lock components before affixing the entire unit to the door A The small indents on the cross of the over ride shaft in line horizontally B The nylon washer and the spring washer not for lever feel on the drive tube C The lever catch in the out position D Cylinder and 2 keys for 630 K C included in the hardware bag 1 Upon unpacking the lock housing with mechanical o...

Page 13: ...ill not work Fig 6 countersink in the top position Fig 7 countersink in the bottom position 3 Insert the cylinder into the lever handle see Fig 3 4 Put the cylinder plug into the lever see Fig 4 5 Making sure that the cylinder plug does not fall out insert the key into the cylinder The key will be horizontal See Fig 5 3 Preparing the Lever Handle and Cylinder for Installation 4 Steps to attach the...

Page 14: ...s turned If it does it was not assembled correctly as shown in step 4 Fig 6 7 Release the lever handle Insert the small screwdriver T page 10 into the small hole on the underside of the lever handle and push in the lever catch Re do steps 2 3 4 5 right handed lock left handed lock Fig 10 If it is not possible to turn the key counter clockwise to complete this step the spring washer D see page 10 m...

Page 15: ...cess Step 6 Very Important To verify that the lever handle has been correctly attached to the housing Fig 11 16 Without using the key turn the lever handle clockwise for Right handed locks or coun ter clockwise for Left handed locks The inside drive hub should not rotate when the handle turns Fig 12 17 With the lever handle in the horizontal posi tion insert the key into the cylinder and turn it c...

Page 16: ...e above operation turn key clockwise until it stops latch and deadbolt must retract complete ly Verify the functionality of the override after the lock is installed on the door Fig 16 Fig 17 23a Loosen the set screw 01 to free the lever using Allen Key P1 Approx 1 4 turn 24 Remove the cap from the lever handle see step 23 Fig 16 25 Insert key 26 Turn the key clockwise until it stops 27 Release key...

Page 17: ...ith the key card or key override Do not close the door until you are certain that you have installed the unit correctly Note The lever handle must stay in the hori zontal position when turning the key do not try to turn the key while turning the handle or the override mechanism will not work Fig 19 Fig 20 Right handed lock Left handed lock Preparing the lever handle for Best Removable Core F 5 Ins...

Page 18: ...r ference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Consult the dealer or an experienced radio TV tech nician for help Statement according to FCC part 15 21 Modifications not expressly approved by Kaba Ilco could void the user s authority to operate the equip ment Statement according to FCC part 15...

Page 19: ...19 E 730 630 750 79E RT Series Installation Guide PK3677_T_04_16 ...

Page 20: ...7 468 3555 1 514 340 9025 Saflok 1 800 999 6213 1 248 837 3700 General Information www kabalodging com Online Consumable Orders www ilcostore com www saflokstore com To access all of our easy steps please visit our Support Website www kabalodgingsupport com ...

Reviews: