background image

 

 

 

 

 

 

 

 

 

Revision level 16.09.04 

Kaba Mauer GmbH  –  Frankenstr. 8-12  –  D-42579 Heiligenhaus  –  Tel.: +49/2056/596-0 – Fax: +49/2056/596-139 – www.kaba-mauer.de

 

Mounting instructions 70171 Varios E 

 

 

In cases where the Kaba Mauer key guide is are not used, the maximum cross sectional area of the keyhole in the door of 

the secure storage unit and/or the lock armour plating may not exceed the dimensions given in Fig. 2 considering DIN 

2768-mH.  

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fig. 2: Max. cross sectional area of keyhole 

 

 

For installation and adjustment of the lock on the door, make sure that the key can be inserted into the lock without 

having to apply force and without jamming. This can be achieved by mounting the lock according to the following 

pattern of mounting holes (Fig. 3). For further lock dimensions please refer to the Kaba Mauer Catalogue Sheet.  

 

 

               

41

49

66,7

 

 

 

 

 

 

Fig. 3: Fastening hole pattern 

 

 

Technical data: 

 

 

Lift height of bolt 12 mm 

 

 

Bolt in fully extended position: approx. 14 mm 

 

 

The maximum allowable force acting on the key bolt against the blocking direction, the maximum locking force and the 

lateral load acting on the bolt, correspond to 1 KN and should not exceed this value. Provision should be made design wise 

for bolt stoppers on both ends or for a bolt support. 

 

 

The actuating turning moment on the key may not exceed 2.5 Nm 

 

 

Fastening of the boltwork: via two M4 threads on the front end of the bolt head 

 

 

Optional fastening of the boltwork: via an adapter plate with drift pin in the bolt head 

 

 

Elektronische Freigabefunktion 

 

Time delay, four-eye identification, remote release 4 wire cable, 250 mm, cable end stripped and tined 

 

Interface 

Functional elements 

Specification 

Cyclic duration 

Input 

Release magnet (red/black) 

563 ohms, Umin=5V DC 

5 – 12V: 100% ED / 24V: 87 

Output 

Key switching contact (orange / brown) 

normally open contact,  

50 mA, 30V DC 

 

 

Varios E 

X (mm) 

Y (mm) 

70171 

11,5 

11,5 

7,5

ma

x.

O

12

ma

x.

max. X

max. Y

 

Reviews: