Mounting Instructions 82021 Code-Combi K 

 

 

Fastening screws: minimum property class 4.8 and maximum property class 8.8. 

 

 

Screws to be secured either by lock washer, flat spring, tooth lock washer, fan type lock washer considering the diameter 
(d1) or to be cemented. 

 

 

Screw tightening moment : minimum 5 Nm and maximum 6 Nm. 

 

 

The bolt must be floating in installed condition. 

 

 

Perfect function of the lock and of any additional connected or triggered systems (e.g. boltworks) must be warranted and 
checked by specialists during installation of the lock.  

 

 

The lock must be mounted in closed condition (bolt extended). 

 

 

The opening (cable gland) in the door of the secure storage unit may not be greater than 100 sq mm (see mounting 
diagrams on Page 5 and following). 

 

 

The lock is designed for installation in secure storage units made of steel. Installation in storage units consisting of other 
material e.g. plastic is not allowed. 

 

 

Do not apply any kind of force (e.g. hammer blows) for screw fitting and adjustment of the lock. 

 

  Lock to be installed covered and so as to prevent opening by boring. 

 

  The square spindle must be inserted without jamming. 

 

 

For installation and adjustment of the lock on the door, make sure that the square spindle can be inserted into the lock 
without applying force and without jamming. This can be achieved by mounting the lock according to the following pattern of 
mounting holes (page 5 and following). For further lock dimensions please refer to the Kaba Mauer Catalogue Sheet. 

 
 

Technical data: 

 

  Lift height of bolt 20 mm  

 

  Bolt extension in locked-out condition: approx. 22 mm 

 

  Bolt width: 40 mm; Bolt height: 9 mm 

 

  The maximum allowable force acting on the key bolt in opposite direction to the direction of locking, the maximum locking 

force and the lateral load acting on the bolt, correspond to 1 KN and should not exceed this value. Provision should be made 
design wise for bolt stoppers on both ends or for a bolt support.  

 

  The  bolt  was  according  to  EN1300  with  a  permanent  load  of  2,5  N  over  10.000  cycles  tested.  These  load  should  not  be 

exceeded permanently. 

 

  The actuating torque on the spindle must not exceed 2.5 Nm.  

 

  Fastening of the boltwork: via two M4 threads on the front end of the bolt head. 

 

Fig. 2: Mounting plate measurements 

 
 
 
 
 
 
 
 
 
 
 
 

O

10

O

8,5

O

10

O

12

59

40

60

59

40

100

97

35

23,5

30

Montageplatte

 

Summary of Contents for Code-Combi K 82021

Page 1: ...areas are not attacked Make sure that the ingress of dirt or detergents e g remaining fillers or cold cleaners is prevented Do not grease oil the lock or key It is recommended that unauthorized person...

Page 2: ...o as to prevent opening by boring The square spindle must be inserted without jamming For installation and adjustment of the lock on the door make sure that the square spindle can be inserted into the...

Page 3: ...nput unit and fix with screws There are two possibilities of fixing the input unit 1 From the inside of the door see Fig 4 with M4 countersunk screws or 2 From the outside of the door see Fig 5 with M...

Page 4: ...ode Combi K 5 Assembly Diagrams Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock R iegel oben 62 O 1 0 1 04 5 3 3 6 67 Cable...

Page 5: ...21 Code Combi K Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock 83 5 97 23 5 3 4 59 O 1 0 O 1 0 R iegel linksK n opf links...

Page 6: ...Code Combi K Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock R iegel oben 62 O 1 0 1 04 5 3 3 6 67 R iegel rechtsK n opf re...

Page 7: ...1 Code Combi K Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock 33 6 1 04 5 O 1 0 62 R ieg el u n ten 67 83 5 97 23 5 3 4 59...

Page 8: ...of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock R iegel rechtsK n opf rechts O 4 2 83 5 23 5 97 O 1 0 O 1 0 59 34 R iegel rechtsK n opf rechts O...

Page 9: ...ns 82021 Code Combi K Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock 90 23 5 97 59 O 1 0 O 1 0 O 4 2 K nopf u nten Cable l...

Page 10: ...21 Code Combi K Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock 83 5 97 23 5 3 4 59 O 1 0 O 1 0 R iegel linksK n opf links...

Page 11: ...ons 82021 Code Combi K Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock O 1 0 33 6 1 04 5 62 R iegel rechts 67 90 23 5 97 59...

Page 12: ...Code Combi K Installation position of lock Installation position of input unit Hole dimensions of input unit Screw fixing points for lock R iegel rechtsK n opf rechts O 4 2 83 5 23 5 97 O 1 0 O 1 0 59...

Reviews: