Stand 17.02.2016
Seite 2 von 12
Mounting Instructions 82021 Code-Combi K
Fastening screws: minimum property class 4.8 and maximum property class 8.8.
Screws to be secured either by lock washer, flat spring, tooth lock washer, fan type lock washer considering the diameter
(d1) or to be cemented.
Screw tightening moment : minimum 5 Nm and maximum 6 Nm.
The bolt must be floating in installed condition.
Perfect function of the lock and of any additional connected or triggered systems (e.g. boltworks) must be warranted and
checked by specialists during installation of the lock.
The lock must be mounted in closed condition (bolt extended).
The opening (cable gland) in the door of the secure storage unit may not be greater than 100 sq mm (see mounting
diagrams on Page 5 and following).
The lock is designed for installation in secure storage units made of steel. Installation in storage units consisting of other
material e.g. plastic is not allowed.
Do not apply any kind of force (e.g. hammer blows) for screw fitting and adjustment of the lock.
Lock to be installed covered and so as to prevent opening by boring.
The square spindle must be inserted without jamming.
For installation and adjustment of the lock on the door, make sure that the square spindle can be inserted into the lock
without applying force and without jamming. This can be achieved by mounting the lock according to the following pattern of
mounting holes (page 5 and following). For further lock dimensions please refer to the Kaba Mauer Catalogue Sheet.
Technical data:
Lift height of bolt 20 mm
Bolt extension in locked-out condition: approx. 22 mm
Bolt width: 40 mm; Bolt height: 9 mm
The maximum allowable force acting on the key bolt in opposite direction to the direction of locking, the maximum locking
force and the lateral load acting on the bolt, correspond to 1 KN and should not exceed this value. Provision should be made
design wise for bolt stoppers on both ends or for a bolt support.
The bolt was according to EN1300 with a permanent load of 2,5 N over 10.000 cycles tested. These load should not be
exceeded permanently.
The actuating torque on the spindle must not exceed 2.5 Nm.
Fastening of the boltwork: via two M4 threads on the front end of the bolt head.
Fig. 2: Mounting plate measurements
O
10
O
8,5
O
10
O
12
59
40
60
59
40
100
97
35
23,5
30
Montageplatte