F-S2000 ELECTRIC BOLT ACTION LOCK 
                INSTALLATION MANUAL  

POWER SUPPLY:DC12V 1A. 

OPERATION CURRENT 850mA, HOLDING CURRENT 300mA . 

FAIL-SAFE TYPE (POWER LOCK) 

 DOOR SENSOR:N.C. & N.O 

 OPERATION DELEAY TIME:0 SEC. 2.5SEC. 5SEC. 9SEC. 

 BUILT-IN DELAYED EGRESS CONTROL POINT 

 FACE PLATE:200mm(L)x32mm(W)x40mm(D) 

 STRIKE PLATE:90mm(L)x26mm(W)x2mm(D) 

PUSH BUTTON

 

AP-10 

DC 12V 
    1A 

+DC12V 

RED 

N.O. 

F-S2000 

N.C. 

COM 

READER 

ORANGE 

Please switch on the appliance again to validate any adjustment of  

    DIP switch value  

      0 SEC. 

     2.5 SEC. 

      5 SEC. 

      9 SEC. 

Setting door lock delay timer : 

BROWN 

 F-S2000

  (6

 PIN  

RED         :  + DC12V 

BROWN  :  GND 

YELLOW :  DOOR POSITION SENSOR(N.C.) 
GREEN    :  DOOR POSITION SENSOR(COM.) 

ORANGE :  PUSH BUTTON 

BLUE       :  DOOR POSITION SENSOR(N.O.) 

Page  1 

Summary of Contents for F-S2000

Page 1: ...POINT FACE PLATE 200mm L x32mm W x40mm D STRIKE PLATE 90mm L x26mm W x2mm D PUSH BUTTON AP 10 DC 12V 1A DC12V RED N O F S2000 N C COM READER ORANGE Please switch on the appliance again to validate any adjustment of DIP switch value 0 SEC 2 5 SEC 5 SEC 9 SEC Setting door lock delay timer BROWN F S2000 6 PIN RED DC12V BROWN GND YELLOW DOOR POSITION SENSOR N C GREEN DOOR POSITION SENSOR COM ORANGE PU...

Page 2: ...ims 5 x 8 mm Strike plate template Time sec X4 Small metal screws for strike plate and shims 4 x 26 mm X 2 Large wood screws for lock body 5 x 15 mm 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 900 800 700 400 600 500 300 200 100 Delay Time Setting Start Stand by Door Close 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 65 60 55 40 50 45 35 30 25 70 Current mA Time sec Time min Temperature Supply p...

Page 3: ...doors Important For vertical mounting wires must come out the top of the unit Instruction Diagram 1 Dimensions Diagram 2 For double door mounting Diagram 3 For single door mounting Diagram 4 For vertical mounting Diagram 1 Diagram 2 Diagram 3 Diagram 4 Page 3 ...

Page 4: ...lease check power supply 2 Please check if the direction of the template is being installed correctlly 3 Please check the connection points N O or N C Lock will open when force is applied on the reader eg Hitting hard or vibrating the reader 1 Please check all the connections 2 Reader s N C points might strike immediately when force is being applied on it this eventually causes the fail safe type ...