background image

Strike plate 

Faceplate 

20mm 

Installation: 

Please make sure the correct  
direction of the shims when mounted 

For hollow metal doors: 

For wood doors: 

45mm 

Drill hole for deadbolt 
(If wood door) 

Drill hole for magnet 
(if wood door) 

Door 

The lock is hot

?

The operating temperature of the lock is normally within 55

.

No operation after installation

?

1.Please check power supply. 2.Please check if the direction of
the template is being installed correctlly 3.Please check the
connection points(N.O or N.C)

Lock will open when force is applied on the reader (eg. Hitting

hard or vibrating the reader).

?

1.Please check all the connections .
2.Reader's N.C points might strike immediately when force is
being applied on it this eventually causes the fail-safe type of lock
to open when sudden power cut occured. Please refer to page 1
for wiring to prevent such case happen.

Question & Answer

19.6.V1.E 

Page  4 

Summary of Contents for F-S2000

Page 1: ...POINT FACE PLATE 200mm L x32mm W x40mm D STRIKE PLATE 90mm L x26mm W x2mm D PUSH BUTTON AP 10 DC 12V 1A DC12V RED N O F S2000 N C COM READER ORANGE Please switch on the appliance again to validate any adjustment of DIP switch value 0 SEC 2 5 SEC 5 SEC 9 SEC Setting door lock delay timer BROWN F S2000 6 PIN RED DC12V BROWN GND YELLOW DOOR POSITION SENSOR N C GREEN DOOR POSITION SENSOR COM ORANGE PU...

Page 2: ...ims 5 x 8 mm Strike plate template Time sec X4 Small metal screws for strike plate and shims 4 x 26 mm X 2 Large wood screws for lock body 5 x 15 mm 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 900 800 700 400 600 500 300 200 100 Delay Time Setting Start Stand by Door Close 0 10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 65 60 55 40 50 45 35 30 25 70 Current mA Time sec Time min Temperature Supply p...

Page 3: ...doors Important For vertical mounting wires must come out the top of the unit Instruction Diagram 1 Dimensions Diagram 2 For double door mounting Diagram 3 For single door mounting Diagram 4 For vertical mounting Diagram 1 Diagram 2 Diagram 3 Diagram 4 Page 3 ...

Page 4: ...lease check power supply 2 Please check if the direction of the template is being installed correctlly 3 Please check the connection points N O or N C Lock will open when force is applied on the reader eg Hitting hard or vibrating the reader 1 Please check all the connections 2 Reader s N C points might strike immediately when force is being applied on it this eventually causes the fail safe type ...

Reviews: