17
Figure 16 - Tube-Cable Assembly Relationships
H
IGH
S
ECURITY
P
EDESTRIAN
D
OOR
L
OCK
I
NSTALLATION
Preliminary Lock Installation
WARNING:
The electronics in the X-09 are susceptible to damage from Electro Static Discharge (ESD).
Make sure you are properly grounded before removing the lock cover and be careful to avoid touching
the connectors on the card.
1.
Remove the two screws from the lock back cover assembly. Hold the case and
pull the cover straight out
from the lock case so as not to bend any of the motor pins on the card assembly
.
Caution:
The drive cam assembly is only retained by the lock back
cover assembly. Be careful that it does not fall out when the cover
is removed.
2.
Remove the drive cam assembly from the lock case assembly.
3.
Remove the protective casing from the end of the cables.
4.
Refer to Figure 16. Feed the cables through the outer, larger, tube
starting from the flared end of the tube. Seat the tube into position
on the tube retainer on the back of the lock case assembly. Be
careful to keep the cables pulled taut while seating the tube to avoid
pinching damage to them.
Alternate Method:
Depending on the width of the door, it may be easier to insert the non-flared end of
the outer tube through the spindle hole from the inside of the container and feed the cables through
the tube. Then seat the flared end of the tube on the tube retainer.
5.
Place the 3.5 x 5 x 1/8 inch hardplate against the back of the CDX-09 lock case assembly.
6.
Feed the cables and outer tube through the 0.5 inch hole in the door while positioning the CDX-09 and
hardplate against the door. Insert and tighten slightly two #10-32 screws nearest the strike opening (top and
bottom) to attach the CDX-09 and hardplate to the door.
Drive Cam
Assembly
Thermal
Relocker
Actuator
Inside Lock Case Assembly