For Professional Technical Support call 1-844-242-2475                                                                                                                          3 

 

17.  Follow all local electrical and safety codes, along with the National Electrical Code (NEC). In addition, all 

Occupational Safety and Health Administration (OSHA) guidelines must be followed. 

18.  The motor of this pump has a thermal protector that will trip if the motor becomes too hot. The protector will reset 

itself once the motor cools down and an acceptable temperature has been reached. The pump may start 

unexpectedly if it is plugged in. 

19.  Ensure the electrical power source is adequate for the requirements of the pump. 

20.  This pump is made of high-strength, corrosion-resistant materials. It will provide trouble-free service for a long time 

when properly installed, maintained, and used. However, inadequate electrical power to the pump, dirt, or debris 

may cause the pump to fail. Please carefully read the manual and follow the instructions regarding common pump 

problems and remedies. 

 

PRE-INSTALLATION 

APPLICATION 

Submersible sewage pumps and designed for pumping sewage, effluent, wastewater or flooded water with up to 2 inch 

solids. 

The pump is built with overload thermal protections and auto reset. The pump is equipped with a 1

0’ 3-prong 

grounding-type power cord and piggyback-style switch for automatic or manual operation. Ball bearings on motor shafts 

never need lubrication. 

TOOLS REQUIRED 

 

 

 

 

 

 

 

 

 

MATERIALS REQUIRED (NOT INCLUDED) 

 

 

 

 

 

 

 

Thread Tape 

2

” Check 

Valve 

2’’ ABS or PVC 
Pipe 

ABS or PVC 
Cement 
(to match the pipe) 

2

” 90° 

Elbow 

Phillips 

Screwdrive

Flathead 

Screwdriver 

Safety 

Goggles 

Tape  

Measure 

Channel 

Locks 

Pipe Wrench 

Cable Ties 

Hacksaw 

Summary of Contents for PUMPS SWW05002TPK

Page 1: ...the store call K2 Customer Service 8 a m 6 p m EST Monday Friday 1 844 242 2475 2019 Copyright GP Enterprises Co Ltd Rev 11 4 19 SWW05002TPK SWW07503TPK Model SWW05002TPK SWW05002VPK SWW07503TPK SWW05...

Page 2: ...at all times when working with pumps 9 This unit is designed only for use on 115 volts single phase 60 Hz and is equipped with an approved 3 conductor cord and 3 prong grounded plug Do not remove the...

Page 3: ...time when properly installed maintained and used However inadequate electrical power to the pump dirt or debris may cause the pump to fail Please carefully read the manual and follow the instructions...

Page 4: ...solids present in suspension in the fluid To meet minimum flow requirements the minimum pipe size is 2 Use a 2 5 1 cm swing check valve in pump discharge to prevent backflow of liquid into sump basin...

Page 5: ...ball must be 2 in above the inlet of the pump 3 Tie the power cords of pump and vertical switch to the discharge pipe with cable tie not included Electrical WARNING Risk of electric shock Can shock bu...

Page 6: ...off to the pump Remember the pump should be connected only to a properly grounded GFCI outlet 1 Make certain the pump is submerged in water Running the pump dry can damage the shaft seal 2 Plug the p...

Page 7: ...sassembly may cause leakage or dangerous electrical wiring issues Do not lift up the pump by the power cord For SWW05002TPK SWW05002VPK SWW05001VPK SWW07501VPK SWW05001TPK SWW07501TPK Before removing...

Page 8: ...rate 1 Check to be sure that the power cord is securely plugged into an outlet Disconnect power to the outlet before handling the pump or motor 2 Check to be sure you have electrical power 3 Check tha...

Page 9: ...to a K2 Sales and Service Center for warranty service cost of shipping will be paid one way This warranty does not apply to products purchased outside of the United States including its territories a...