13
CrossRail Tilt Up Install Dimensions
The CrossRail Tilt Up System is a fully customizable solution. Figure 2 and Table 1 below provide
recommended installation dimensions based upon a standard 60-cell and 72-cell PV module with
1/6 - point clamping locations. Always ensure that the dimensions are suitable for the project site.
Dimension
Description
Desired Tilt Angle
15 Degrees
10 Degrees
7 Degrees
Portrait
Landscape
Portrait
Landscape
Portrait
Landscape
60-Cell
72-Cell
60 & 72
60-Cell
72-Cell
60 & 72
60-Cell
72-Cell
60 & 72
A
Front Leg
54.5
62
39
54.5
62
39
54.5
62
39
B
Rear Leg
15
16.5
10
9.5
11
6.75
6.5
7.5
4.75
C
L-Foot Spacing
54
64
40
53
63
39.5
52.5
62.5
39
D
Rail Offset
5
5
5
5
5
5
5
5
5
E
Module Length
65
79
39.5
65
79
39.5
65
79
39.5
F
Rear Module
Height
22
25
10
17
18
7
14
15
5
G
Front Module
Height
3 1/3
3 1/3
3 1/3
3 7/8
3 7/8
3 7/8
4 1/8
4 1/8
4 1/8
Table 1: CrossRail Tilt Up installation dimensions
Note: All dimensions are in inches
*Note: / degree tilted systems in landscape require specific configurations. See Step 7.
Important Notes:
1. Rail Offset not to exceed 8 inches.
2. Rear module height not to exceed 30 inches, Note that dimension provided in Table 1 does not
roof attachment height.
3. Front module height dimension does not include roof attachment height.
4. Refer to CrossRail Tilt Up Engineering Letter(s) for reaction loads at L-Feet.
5. Always refer to chosen PV module manufacturer’s installation instructions for approved clamping
locations. Dimensions in Table 1 assume a standard 60-cell or 72-cell module with clamping locations
at the 1/6-points on the module’s long edge.
6. Installer is responsible for cutting rail to lengths specified “A” and “B” in Table 1.
7. Dimensions provided in Table 1 are suggested values. Installer shall verify dimensions are appropriate
for the individual site conditions, selected PV module and roof surface.
8. Adjust based on your installation needs.